MDO3000 Programmer Manual.pdf - 第859页

Commands Listed in Alphabetical Order TRIGger:A:BU S:B<x>:LIN:DA T a:V ALue This command specifies the binary data string to be used for LIN trigger c ond ition if trigger condition is ID or IDANDDA T A. Conditions …

100%1 / 1158
Commands Listed in Alphabetical Order
Arguments
LESSthan sets t
he LIN data qualifier to less than.
MOREthan sets the LIN data qualifier to greater than.
EQual sets the LIN data qualifier to equal.
UNEQual sets the LIN data qualifier to not equal.
LESSEQual sets the LIN data qualifier to less than or equal.
MOREEQual sets the LIN data qualifier to greater than or equal.
INrange sets the LIN data qualifier to in range.
OUTrange s
ets the LIN data qualifier to out of range.
Examples
TRIGGER:A:BUS:B1:LIN:DATA:QUALIFIER OUTRANGE sets the data qualifier
to out of range.
TRIGGER:A:BUS:B1:LIN:DATA:QUALIFIER? might return
TRIGGER:A:BUS:B1:LIN:DATA:QUALIFIER EQUAL indicating the data
qualifier is set to equal.
TRIGger:A:BUS:B<x>:LIN:DATa:SIZe
This command specifies the length of the data string in bytes to be used for LIN
trigger.
B<x>
Conditions
This command requires a DPO4AUTO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AUTO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:DATa:SIZe <NR1>
TRIGger:A:BUS:B<x>:LIN:DATa:SIZe?
Argu
ments
<NR1> is the size of the data string in bytes.
Examples
TRIGGER:A:BUS:B1:LIN:DATA:SIZE 8 sets the data size to 8 bytes.
TRIGGER:A:BUS:B1:LIN:DATA:SIZE? might return
TRIGGER:A:BUS:B1:LIN:DATA:SIZE 1 indicating the data size is 1 byte.
2-828 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
TRIGger:A:BU
S:B<x>:LIN:DATa:VALue
This command specifies the binary data string to be used for LIN trigger condition
if trigger condition is ID or IDANDDATA.
Conditions
This command requires a DPO4AUTO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AUTO application module for
MDO3000 mo
dels.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:DATa:VALue <QString>
TRIGger:A:BUS:B<x>:LIN:DATa:VALue?
Arguments
<QString> is a quoted string that is the LIN trigger data value.
Examples
TRIGGER:A:BUS:B1:LIN:DATA:VALUE “11001101sets the data value to
11001101.
TRIGGER:A:BUS:B1:LIN:DATA:VALUE? might return
TRIGGER:A:BUS:B1:LIN:DATA:VALUE "XXXXXXXX" indicating the
data value is don't care.
TRIGger:A:BUS:B<x>:LIN:ERRTYPE
This command specifies the error type be used for LIN trigger. B<x>
Conditions
This command requires a DPO4AUTO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AUTO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:ERRTYPE
{SYNC|PARity|CHecksum|HEADertime|RESPtime|FRAMetime}
TRIGger:A:BUS:B<x>:LIN:ERRTYPE?
Arguments
SYNC sets the LIN error type to SYNC.
PARity sets the LIN error type to parity.
CHecksum sets the LIN error type to checksum.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-829
Commands Listed in Alphabetical Order
HEADertime set
s the LIN error type to header time.
RESPtime sets the LIN error type to response time.
FRAMetime sets the LIN error type to frame time.
Examples
TRIGGER:A:BUS:B1:LIN:ERRTYPE CHECKSUM sets the LIN error type to
checksum.
TRIGGER:A:BUS:B1:LIN:ERRTYPE? might return
TRIGGER:A:BUS:B1:LIN:ERRTYPE SYNC indicating the LIN error type
is SYNC.
TRIGger:A:BUS:B<x>:LIN:IDentier:VALue
This command specifies the binary address string used for LIN trigger if the
trigger condition is ID or IDANDDATA.
B<x>
Conditions
This command requires a DPO4AUTO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AUTO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Arguments
<QString> is the binary address string used for LIN trigger if the trigger
condition is ID or IDANDDATA.
Examples
TRIGGER:A:BUS:B1:LIN:IDENTIFIER:VALUE "110010" sets the identifier
value to 110010.
TRIGGER:A:BUS:B1:LIN:IDENTIFIER:VALUE? might return
TRIGGER:A:BUS:B1:LIN:IDENTIFIER:VALUE "XXXXXX" indicating the
identifier value is XXXXXX.
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue
When the MIL-STD-1553 bus trigger condition is set to CO MMAND,andthe
qualifier is set to
INrange or OUTrange, this command s
pecifies the upper
limit of the range for the remote terminal address field. (Use the command
2-830 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual