Commands Listed in Alphabetical Order TRIGger:A:BUS :B<x>:MIL1553B:COMMAND:ADDR ess:V ALue to specify the lower limit of the range.) The default is all X’ s (don’t care). B<x> Conditions This command requires…

Commands Listed in Alphabetical Order
HEADertime set
s the LIN error type to header time.
RESPtime sets the LIN error type to response time.
FRAMetime sets the LIN error type to frame time.
Examples
TRIGGER:A:BUS:B1:LIN:ERRTYPE CHECKSUM sets the LIN error type to
checksum.
TRIGGER:A:BUS:B1:LIN:ERRTYPE? might return
TRIGGER:A:BUS:B1:LIN:ERRTYPE SYNC indicating the LIN error type
is SYNC.
TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue
This command specifies the binary address string used for LIN trigger if the
trigger condition is ID or IDANDDATA.
B<x>
Conditions
This command requires a DPO4AUTO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AUTO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue <QString>
TRIGger:A:BUS:B<x>:LIN:IDentifier:VALue?
Arguments
<QString> is the binary address string used for LIN trigger if the trigger
condition is ID or IDANDDATA.
Examples
TRIGGER:A:BUS:B1:LIN:IDENTIFIER:VALUE "110010" sets the identifier
value to 110010.
TRIGGER:A:BUS:B1:LIN:IDENTIFIER:VALUE? might return
TRIGGER:A:BUS:B1:LIN:IDENTIFIER:VALUE "XXXXXX" indicating the
identifier value is XXXXXX.
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue
When the MIL-STD-1553 bus trigger condition is set to CO MMAND,andthe
qualifier is set to
INrange or OUTrange, this command s
pecifies the upper
limit of the range for the remote terminal address field. (Use the command
2-830 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
TRIGger:A:BUS
:B<x>:MIL1553B:COMMAND:ADDRess:VALue to specify
the lower limit of the range.) The default is all X’s (don’t care).
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue
<QString>
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue?
Related Commands
TRIGger:A:BUS:B<x>:MIL1553B:CONDition
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue
Arguments
QString is a quoted string of up to 5 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the leas
tsignificant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:MIL1553B:HIVALue “01000” sets the upper limit of the
remote terminal address range to 01000 (when the trigger condition has been set
to
MIL1553B, and the qualifier has been set to INrange or OUTrange).
TRIGger:A:BUS:B1:MIL1553B:HIVALue?
might return “XXXXX”.
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier
When the MIL-STD-1553 bus trigger condition is set to COMMAND, this command
specifies the qualifier to
be used with the remote terminal address field.
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Trigger
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-831

Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier
{LESSthan|MOREthan|EQual|UNEQual|LESSEQual|MOREEQual|
INrange|OUTrange}
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier?
Related Commands
TRIGger:A:B
US:B<x>:MIL1553B:COMMAND:ADDRess:VALue
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue
Arguments
LESSthan sets the Command Address qualifier to less than.
MOREthan sets the Command Address qualifier to greater than.
EQual sets the Command Address qualifier to equal.
UNEQual sets the Com
mand Address qualifier to not equal.
LESSEQual sets the Command Address qualifier to less than or equal.
MOREEQual sets the Command Address qualifier to greater than or equal.
INrange sets the Command Address qualifier to in range.
OUTrange sets the Command Address qualifier to out of range.
Examples
TRIGger:A:BUS:B1:MIL1553B:COMMAND:ADDRess:QUALifier EQual sets
the qualifier to be used with the remote terminal address to equal.
TRIGger:A:BUS:B1:MIL1553B:COMMAND:ADDRess:QUALifier? might
return INRANGE.
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:VALue
When the MIL-STD-1553 bus trigger condition is set to CO MMAND,andthe
qualifier is set to
LESSthan, MOREthan, EQual, UNEQual, LESSEQual
or MOREEQual, this command specifies the value of the 5–bit remote terminal
address to be used in the trigger. When the MIL-STD-1553 bus trigger condition
is set to
COMMAND, and the qualifier is set to INrange or OUTrange, this
command specifies the lower limit of the remote terminal address range. The
default is all X’s (don’t care).
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Trigger