MDO3000 Programmer Manual.pdf - 第868页

Commands Listed in A lphabetical Order NOTE. Use the TRIGger:A:BUS :B< x>:MIL1553B:COND ition:STATus:BI T commands to se t the following bits: 9 — me ssage error TRIGger:A: BUS:B<x>:MIL1553B:ST AT us:BIT :ME …

100%1 / 1158
Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:MIL1553B:CONDition
{SYNC|COMMAND|STATus|DATA|TIMe|ERRor}
TRIGger:A:BUS:B<x>:MIL1553B:CONDition?
Related Commands
Most of the other TR IGger:A:BUS:B<x>:MIL1553B commands are impacted
by the setting of this command.
BUS:B<x>:MIL1553B:POLarity
BUS:B<x>:MIL1553B:SOUrce
Arguments
SYNC refers to the 3–bit sync pulse that precedes each word.
COMMAND is one of 3 16–bit word types. It specifies the function that a remote
terminal is to perform.
STATus is one of 3 16–bit word types. Remote terminals respond to valid message
transmissions via status words.
DATA is one of 3 16–bit word types.
TIMe specifies to trigger on either the RT (remote terminal response time), or
the IMG (Inter-message Gap). Use the commands TRIGger:A:BUS:B<x>:
MIL1553B:TIMe:QUALifier, TRIGger:A:BUS:B<x>:MIL1553B:TIMe:
LESSLimit,andTRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit to
specify the time parameters.
ERRor specifies to trigger upon a signaling error. (You can specify which type
of error Parity, Sync, Manchester or Non-contiguous Data by using the
TRIGger:A:BUS:B<x>:MIL1553B:ERRTYPE command.)
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-837
Commands Listed in Alphabetical Order
NOTE.
Use the
TRIGger:A:BUS :B<x>:MIL1553B:CONDition:STATus:BIT
commands to se
t the following bits:
9 me ssage error
TRIGger:A:
BUS:B<x>:MIL1553B:STATus:BIT:ME
10 instrumentation
TRIGger:A:
BUS:B<x>:MIL1553B:STATus:BIT:INSTR
11 SRQ (service request)
TRIGger:A
:BUS:B<x>:MIL1553B:STATus:BIT:SRQ
15 BCR (broadcast command received)
TRIGger:
A:BUS:B<x>:MIL1553B:STATus:BIT:BCR
16 busy
TRIGger
:A:BUS:B<x>:MIL1553B:STATus:BIT:BUSY
17 subsystem ag
TRIGge
r:A:BUS:B<x>:MIL1553B:STATus:BIT:SUBSF
18 DBCA (dynamic b us control acceptance)
TRIGg
er:A:BUS:B<x>:MIL1553B:STATus:BIT:DBCA
19 terminal ag
TRIG
ger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF
Examples
:TRIGger:A:BUS:B1:MIL1553B:CONDition STATus sets the word type to
trigger on to
STATus.
:TRIGger:A:BUS:B1:MIL1553B:CONDition? might return DATA.
TRIGger:A:BUS:B<x>:MIL1553B:DATa:PARity
When the MIL-STD-1553 bus trigger condition is set to DATa, this command
specifies the data parity bit to be used in the trigger. Returned values are 0,1,or
X (don’t care).
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Trigger
2-838 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:MIL1553B:DATa:PARity
{0|1|X|ZERo|ONE|NOCARE|OFF|ON}
TRIGger:A:BU
S:B<x>:MIL1553B:DATa:PARity?
Related Commands
TRIGger:A:BUS:B<x>:MIL1553B:CONDition
TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue
Arguments
0
1
X
sets the value to X (“don’t care”) which is the default.
ZERO sets the value to 0.
ONE sets the value to 1.
NOCARE sets the value to X (“don’t care”) which is the default.
OFF sets the value to 0.
ON sets the value to 1.
Examples
TRIGger:A:BUS:B1:MIL1553B:DATa:PARity 1 sets the data parity bit to be
used in a MIL-STD-1553 bus trigger to 1.
TRIGger:A:BUS:B1:MIL1553B:DATa:PARity? might return 0, indicating that
the data parity bit to be used in a MIL-STD-1553 bus trigger is set to 0.
TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue
When the MIL-STD-1553 bus trigger condition is set to DATa, this command
specifies the data binary pattern to be used in the trigger. This is a 16-bit eld.
The default is all X’s (don’t care).
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue <QString>
TRIGger:A:BUS:B<x>:MIL1553B:DATa:VALue?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-839