MDO3000 Programmer Manual.pdf - 第950页

Commands Listed in A lphabetical Order Syntax TRIGger:A:VID eo{:SYNC|:FIELD} {ODD|EVEN|ALL Fields|ALLLines| NUMERic} TRIGger:A:VID eo{:SYNC|:FIELD} ? A rguments ODD argument sets the oscilloscope to tri gger on interlace…

100%1 / 1158
Commands Listed in Alphabetical Order
Table 2-57: Available HDTV formats (cont.)
HDTV format Description
720p50
750 lines (720 active), 1280 x 720 pixel,
progressive, 50 fps
720p60
750 lines (720 active), 1280 x 720 pixel,
progressive, 60 fps
875i60
875 active lines, interlaced, 60 fps
1080i50
1125 Lines (1080 active), 1920 x 1080 pixel,
interlaced, 50 fps
1080i60
1125 lines (1080 active), 1920 x 1080 pixel,
interlaced, 60 fps
1080p24
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 24 fps
1080sF24
1125 lines (1080 active), 1920 x 1080 pixel,
progressive (sF), 2 4 fps
1080p25
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 25 fps
1080P30
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 30 fps
1080P50
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 50 fps
1080P60
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 60 fps
Examples
TRIGGER:A:VIDEO:STANDARD NTSC sets the oscilloscope to trigger on
NTSC-standard video signals.
TRIGGER:A:VIDEO:STANDARD? might return :TRIGger:A:VIDeo:STANDARD
NTSC
indicating that the oscilloscope is set to trigger on an NTSC format.
TRIGger:A:VIDeo{:SYNC|:FIELD}
This command sets the video field to use for triggering on video signals (odd
fields, even fields, all fields, all lines, numeric).
Conditions
This command requires a DPO4VID application module to use any standard
besides NTSc, PAL, or SECAM, except for MDO3000 models, which do not
require an application module.
Group
Trigger
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-919
Commands Listed in Alphabetical Order
Syntax
TRIGger:A:VID
eo{:SYNC|:FIELD}
{ODD|EVEN|ALLFields|ALLLines|NUMERic}
TRIGger:A:VIDeo{:SYNC|:FIELD}?
A
rguments
ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
ALLFields argument sets the oscilloscope to trigger on all fields.
ALLLines argument sets the oscilloscope to trigger on all video lines.
NUMERic argument sets the oscilloscope to trigger on the video signal line
specified by the TRIGger:A:VIDeo:LINE command.
Examples
TRIGGER:A:VIDEO:FIELD EVEN sets the A video trigger so that it will trigger
on even fields.
TRIGGER:A:VIDEO:FIELD? might return :TRIGGER:A:VIDEO:FIELD
ALLFIELDS
indicating that the A video will trigger on all video elds.
TRIGger:B
Sets the B trigger level to 50% of minimum and maximum. The query form
of this command returns the B trigger parameters. This command is similar to
selecting B Event (Delayed) Trigger Setup from the Trigger menu and then
viewing the current setups.
Group
Trigger
Syntax
TRIGger:B SETLevel
TRIGger:B?
Related Commands
TRIGger:A
Arguments
SETLevel sets the B trigger level to 50% of MIN and MAX.
Examples
TRIGGER:B SETLEVEL sets the B trigger level to 50% of MIN and MAX.
TRIGGER:B? might return the following B trigger parameters:
:TRIGGER:B:STATE 0;TYPE EDGE; LEVEL -220.0000E-3;BY
TIME;EDGE:SOURCE CH1;SLOPE RISE;CO UPLING DC; :TRIGGER:B:TIM E
16.0000E-9;EVENTS:COUNT 2
2-920 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
TRIGger:B:BY
Selects or returns whether the B trigger occurs after a specified number of events
or a specified period of time after the A trigger.
Group
Trigger
Syntax
TRIGger:B:BY {EVENTS|TI Me}
TRIGger:B:BY?
Related Commands
TRIGger:B:EVENTS:COUNt, TRIGger:B:TIMe,,
Arguments
EVENTS sets the B trigger to take place following a set number of trigger
events after the A trigger occurs. The number of events is specified by
TRIGger:B:
EVENTS:COUNt.
TIMe sets the B trigger to occur a set time after the A trigger event. The time
period is specified by TRIGger:B:
TIMe.
Examples
TRIGGER:B:BY TIME sets the B trigger to occur at a set time after the A trigger
event.
TRIGGER:B:BY? might return :TRIGGER:B:BY EVENTS indicating that the B
trigger takes place following a set number of trigger events after the A trigger
occurs.
TRIGger:B:EDGE? (Query Only)
Returns the source, slope, and coupling for B trigger.
Group
Trigger
Syntax
TRIGger:B:EDGE?
Related Commands
TRIGger:B:EDGE:COUPling,
TRIGger:B:EDGE:SLOpe,
TRIGger:B:EDGE:SOUrce
Examples
TRIGGER:B:EDGE? might return :TRIGGER:B:EDGE:SOURCE CH1; SLOP E
RISE;COUPLING DC
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-921