POWER UP SEQUENCE
MACHINE POWER UP SEQUENCE
Chapter Issue 3 Jun 01 Installation Manual 6.9
Blue USC To enable the blue under screen cleaner carry out the following:
1. Select Maint. (F8).
2. Select Set Prefs (F5).
3. Select F10 function key on the keyboard, type bluon and select Enter.
4. Set up the machine and filtration units as shown in the table.
5. Press Open Cover (F2) and raise the machine shutter.
6. Remove the solvent tank cap and add solvent to the tank using a funnel.
Replace the cap.
7. With the shutter raised, the menu bar displays the Prime Paper and Prime
Solvent options. Select Prime Solvent (F6) and when prompted press the
two control buttons until the paper is wet, (this may take several attempts
before solvent is sprayed onto the paper).
8. Select Prime Paper (F5) and when prompted press the two control buttons
simultaneously to feed a fresh area of dry paper over the solvent dispense
pipe ensuring that the paper feeds correctly.
9. Lower the machine shutter, press the System button and select Exit (F8).
Vortex USC To enable the Vortex under screen cleaner carry out the following:
1. Select Maint. (F8).
2. Select Set Prefs (F5).
3. Select F10 function key on the keyboard, type vorton and select Enter.
4. Set up the machine and filtration units as shown in the table.
5. Press Open Cover (F2) and raise the machine shutter and lower the drop
down panel.
6. Remove the solvent tank cap and add solvent to the tank using a funnel.
Replace the cap.
Vacuum Non Vacuum
Check the filtration unit is ON,
air flow set to 10
Set the machine transport mode to:
LEFT to LEFT
Set Machine transport mode to:
LEFT to LEFT
Set clean mode to:
1 WET-1 DRY
Set the clean mode to:
WET/VAC WET/DRY
Vacuum Non Vacuum
Check the filtration unit is ON, air flow set to
Max
Set the machine transport mode to LEFT
to LEFT
Set Machine transport mode to LEFT to LEFT

POWER UP SEQUENCE
MACHINE POWER UP SEQUENCE
6.10 Installation Manual Chapter Issue 3 Jun 01
7. With the cover in the up position, the menu bar displays the Prime Solvent
options. Select Prime Solvent (F6) and when prompted press the two
control buttons until the cleaning cassette wet cell is impregnated with
solvent (this may take several attempts before solvent is sprayed onto the wet
cell).
8. Raise the drop down panel and lower the machine shutter, press the System
button and select Exit (F8).
Paste Dispenser Function Check (if fitted)
ProFlow Contact
Position Setup
For machines using ProFlow only, set up the contact height position as follows:
1. In Module Diagnostics Page select Rising Table.
2. Select Home Rising Table. Select Run Diagnost. Select Exit.
3. In Module Diagnostics Page select Camera Axes.
4. Select Home Camera X Axis. Select Run Diagnost.
5. Select Home Camera Y Axis. Select Run Diagnost. Select Exit.
6. In the Module Diagnostics Page select ProFlow.
7. Select Home ProFlow. Select Run Diagnost. Select Exit.
8. In the Module Diagnostics Page select Print Carriage.
9. Select Home Print Carriage. Select Run Diagnost.
10.Select Drive Carriage Using Jog Buttons. Using the jog buttons drive the
Print Carriage to the mid position of the stencil.
11. Load a stencil with an off centre image.
12. At the MMI select Exit to return to Module Diagnostics Page.
13.In the Module Diagnostics Page select ProFlow. Select Adjust on the Menu
Bar.
14.In the ProFlow Adjust Parameters select PFLOW CONTACT POS.
15.At the Menu Bar select Incr. or Decr. to set the Contact Position to 5.5mm.
16.Fit an empty transfer head to the ProFlow pressure mechanism. Remove the
cover.
NOTE
Ensure wipers and skis are fitted to the transfer head.
17.Position a 0.1mm shim on the stencil under the transfer head.
Detail Accept
Set the paste cartridge empty sensor to operate correctly using
the customers solder paste.

POWER UP SEQUENCE
MACHINE POWER UP SEQUENCE
Chapter Issue 3 Jun 01 Installation Manual 6.11
18.In the Module Diagnostics Page select Drive System to Contact Height.
Select Run Diagnost.
NOTE
Correct contact height is when the shim is just held between the transfer head
wipers and stencil. At this position it is not possible to slide the shim
sideways past the transfer head skis. If correct contact height is not yet
achieved, carry out the following steps:
19.Select Adjust on the Menu Bar.
20.In the ProFlow Adjust Parameters select PFLOW CONTACT POS.
21.At the Menu Bar select Incr. or Decr. to increase or decrease the Contact
Position set height by 0.5mm (eg 5.0mm or 6.0mm). Select Exit.
NOTE
Normally the contact position is between the range of 4mm - 8mm (nomi-
nally 6mm).
22.In the Module Diagnostics Page select Drive System to Contact Height.
Select Run Diagnost.
23.Check if contact height is correct, (as detailed in NOTE above). If adjust-
ment is still required repeat Steps 19 to 22 varying the set position until
correct height is achieved.
24.On completion of contact height set up select Home ProFlow on Module
Diagnostics Page. Select Run Diagnost.
25.Remove shim.