ELA Installation.pdf - 第61页
FOREIGN MACHINE INTERFA CE INTRODUCTION Chapter Issu e 3 Jun 01 Installati on Manua l 7.1 CHAP TE R 7 FOREIGN MACHINE INTERF ACE INTRO DUCTION The Foreign Machine I nterface ( FMI) is an electr ical mea ns of com municat…

POWER UP SEQUENCE
MACHINE POWER UP SEQUENCE
6.12 Installation Manual Chapter Issue 3 Jun 01

FOREIGN MACHINE INTERFACE
INTRODUCTION
Chapter Issue 3 Jun 01 Installation Manual 7.1
CHAPTER 7 FOREIGN MACHINE INTERFACE
INTRODUCTION
The Foreign Machine Interface (FMI) is an electrical means of communication
between the ELA machine and an adjacent machine, using electrical signals.
The signals are transferred using opto-couplers and relay contacts which keep
the machines electrically isolated.
The adjacent machine can be upline or downline of the ELA machine in a left-
to-right or right-to-left board transfer arrangement, or it can be at one side of the
ELA machine in a left-to-left or right-to-right arrangement.
The ELA machine can interface with many different types of adjacent machine
which can be of any proprietary manufacture. The adjacent machine utilizes a
set of timing and control signals (protocols) for communication with other
machines. As there are many different protocols, DEK supplies a custom
designed FMI to suit the protocol for each type of adjacent machine.
The FMI hardware comprises:
• A Multi-Interface Unit (MIU) located on the rear of the machine.
• FMI loom connecting the FMI port, on the machine controller, to the MIU.
• Two interface cables, one cable for each adjacent machine.
Figure 7-1 Machine Arrangements for Board Transfers
Left to Right Board Transfers
Right to Left Board Transfers
Left to Left Board Transfers
Right to Right Board Transfers
Upline
Downline
Adjacent
Machine
Adjacent
Machine
ELA
Machine
Upline
Downline
Adjacent
Machine
Adjacent
Machine
ELA
Machine
Upline
Adjacent
Machine
Downline
Adjacent
Machine
Upline
Adjacent
Machine
Downline
Adjacent
Machine
ELA
Machine
ELA
Machine

FOREIGN MACHINE INTERFACE
MODULE OVERVIEW
7.2 Installation Manual Chapter Issue 3 Jun 01
MODULE OVERVIEW
Figure 7-2 Multi-Interface Unit
M01SK1
Signal lines to and from the ELA machine
from the upline machine.
Inputs: Opto-isolated.
Outputs: Open collector output driver.
Relay switched.
M01SK2
Signal lines to and from the ELA machine
from the downline machine.
Inputs: Opto-isolated.
Outputs: Open collector output driver.
Relay switched.
M01SK3
The RS232 link is used for carrying out self
tests on the MIU only and has no function
on the ELA machine.
M01PL1
Power supplies.
Comms connections to this machine
Inputs to the ELA machine from interface -
1. Downline Ready
2. Upline Ready
3. Downline Available
Outputs from the ELA machine to interface -
1. Send Downline
2. Send Upline
3. DEK Available
LED Bank
LD2
Shows the
integrity of
the derived
supplies
LED Bank LD1
Indicates the
sequence of
events during
board transfers
+24V
+24V (E-STOP)
+12V
+5V
DOWNLINE READY
RS 232
DOWNLINE
UPLINE
DEK MACHINE
UPLINE READY
DOWNLINE AVAILABLE
SEND DOWNLINE
SEND UPLINE
DEK M/CN AVAILABLE
MULTI-INTERFACE UNIT
FROM
DEK
MACHINE