FOREIGN MACHINE INTERFACE
PROCEDURE
Chapter Issue 3 Jun 01 Installation Manual 7.5
PROCEDURE
Ensure MIU is configured with the correct protocols for upline and downline
machines as detailed earlier.
1. Power up the machine using the mains isolator, ensure that the air supply is
connected.
The message prompt bar displays - ‘Press SYSTEM Button To Initialize
Printer or Select Diagnostics or Load Data.
2. Press System button, the machine initializes.
3. Select Maint. (F8).
4. Select Set Prefs,(F5).
The Set Preferences window is displayed.
5. Using the Next and Previous keys highlight the Upline Protocol function.
Use the Incr. and Decr. keys to change to the required protocol, eg. Sanyo.
6. Repeat Step 5 for the Downline Protocol. At this stage, if required, change
the Display Units, Transfer Mode etc.
Run
Open
Cover
Paste
Load
Clean
Screen
Adjust Setup Monitor Maint.
Calibrat
Pressure
Calibrat
Offset
Calibrat
Vision
House
Keeping
Set
Prefs
Diagnost
Test
Cycles
Exit
Set Preferences
TRANSPORT MODE
MACHINE UNITS
UPLINE PROTOCOL
DOWNLINE PROTOCOL
TRANSFER PERIOD
SELECTIVE PRINT/PASS
PASTE DISPENSE POS.
COMMS PROTOCOL
EVENT RECORDING
TOOLING HARDWARE
FIDUCIAL REFERENCE
PRESSURE H/W
SCREEN SIZE
CONSUMABLE ACTION
LEFT TO LEFT
Metric
NO FMI
NO FMI
20
DISABLED
FRONT
NO COMMS
GROUP 3
MAGNETIC
LEFT
FITTED
265
WARN
secs
..more
Next Previous Incr. Decr. Exit
FOREIGN MACHINE INTERFACE
PROCEDURE
7.6 Installation Manual Chapter Issue 3 Jun 01
7. When completed select Exit (F8). This saves the revised printer configura-
tion.
8. Select Setup (F6).
9. Select Mode (F1) until the mode displayed changes to No Print.
10.Select Exit (F8).
11.Ensure that the Upline and Downline Machines are connected and are
powered up, (E Stop loop connected if necessary).
12.Select Run (F1). This function key changes, to read Stop.
The screen printer requests a board from the upline machine and pass it through
the machine. The board stops at the sensor on the conveyor. On request from the
downline machine the board passes onto the external conveyor. When the sensor
is clear the screen printer requests another board from the upline machine and
the sequence repeats.
Selecting Stop ceases the sequence, changing the Stop key back to the Run key.
This shows that the interface is working between the screen printer and the
external machines.
Mode
Load
Data
Edit
data
Setup
squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
Run Head
Paste
Load
Clean
screen
Adjust Setup Monitor Maint.
Mode
Load
Data
Edit
data
Setup
squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
Mode
Load
Data
Edit
data
Setup
squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
Run Head
Paste
Load
Clean
Screen
Adjust Setup Monitor Maint.
MACHINE PERFORMANCE
MACHINE CAPABILITY
Chapter Issue 4 Jun 01 Installation Manual 8.1
CHAPTER 8 MACHINE PERFORMANCE
MACHINE CAPABILITY
Load the product file named 265test1 from the hard disk and with a DEK
alignment board loaded ensure that the following parameters are correct:
Screen - Calibration/Dry Align
Squeegee - Length to suit board /ProFlow - Empty Transfer Head
Front & Rear Print Speed - 25mm/sec (squeegees) / 70mm/sec (ProFlow)
Front & Rear Pressure - 5kg (squeegees) / 3kg (ProFlow)
ProFlow Paste Pressure - 2.2 bar
Separation Speed - 1mm/sec.
Under Board Clearance - 20mm
Paste Dispense - 0
Under Screen Rate - 0
Transport Mode - Left to Left
SPC Data Output Rate - Every Cycle
SPC Data Mode - Disk
SPC Format - Windows
SPC Align Inspect Mode - Post Print
Use nine magnetic tooling pins to fully support the board, apply small amount
of paste or suitable lubricant (enough to lubricate squeegees). Record >100 full
machine cycles and setup QC-Cal program as follows:
1. Holding down the Windows button, press E on the keyboard and open
Explorer. If squeegees are fitted ensure the filter files sqy1.qcf and sqy2.qcf
are present in the directory structure C:\Prolink\QcCalc\Filters.
2. Start the QC-Cal program.
3. Select Edit, Data.