AG900 and AG900 S Applicators Customer Product Manual - 第25页
AG − 900+ and AG900+S Applicators 21 2009 Nordson Corporation Part 1098464A 2 3 9 4 6 8 5 1 1 7 Figure 7: AG-900+/AG900+S Applicator Assembly 1. Socket head screws 2. Air cap 3. Spring 4. Module body with piston/cartri…

AG−900+ and AG900+S Applicators
20
Part 1098464A
2009 Nordson Corporation
Repair
WARNING! Allow only personnel with appropriate training and
experience to operate or service the equipment. The use of
untrained or inexperienced personnel to operate or service the
equipment can result in injury, including death, to themselves and
others, and damage to the equipment.
WARNING! Disconnect equipment from line voltage. Failure to observe
thiswarning may result in personal injury, death, or equipment damage.
This section provides procedures for replacing AG-900+/AG900+S parts.
Replace the Needle/Nozzle
Disassembly
To disassemble your applicator to replace the nozzle/needle assemblies, perform the
following procedure:
1. Heated applicators: disconnect and lock out input electrical power from the applicator.
NOTE: Do not remove the module from the regulator body or applicator adapter body
unless applicator location prohibits easy access.
2. If location requires the AG900+/AG900+S module to be removed from the regulator or
adapter block to access components, do so by removing the two socket head screws
from the front of the module and pulling it free.
NOTE: Module must be pulled straight away to avoid damage to locating dowel pins
on back face of module.

AG−900+ and AG900+S Applicators
21
2009 Nordson Corporation
Part 1098464A
2
3
9
4
6
8
5
1
1
7
Figure 7: AG-900+/AG900+S Applicator Assembly
1. Socket head screws
2. Air cap
3. Spring
4. Module body with piston/cartridge and needle
assemblies installed
5. O-ring
6. Nozzle flange
7. Nozzle
8. Back-up ring
9. Large o-ring (top of
piston/cartridge assembly)
3. See Figure 7.Remove the four socket head screws (1), from the air cap (2) and then lift
the cap and spring (3) free of the applicator module.

AG−900+ and AG900+S Applicators
22
Part 1098464A
2009 Nordson Corporation
Disassembly (contd)
4. Remove the existing nozzle from the AG900+/AG900+S module by removing the 4
socket head screws (1) from the nozzle flange (6) (the nozzle will remain attached to the
flange).
5. Remove (unscrew) old nozzle (7) from nozzle flange(6).
6. Push the piston/cartridge assembly and needle assembly (located inside of applicator
module body) out of the top of the module by pressing tip of needle assembly against a
soft surface (i.e. piece of wood or wood work surface).
Module
Body
Piston/Cartridge
Assembly with
Needle Assembly
Figure 8: Removing Piston/Cartridge and Needle Assembly from Module Body
7. Remove large o-ring (9) from top of piston/cartridge assembly.