1.
Introduction ....................................................... 3
2.
Required items ................................................. 3
3.
Specifications and caution points ..................... 4
4.
Enabling hybrid calibration offset measurement
6
5.
Conditions ........................................................ 7
6.
Procedure flow ................................................. 8
7.
Performing changeover .................................... 9
7.1.
Performing changeover for hybrid calibration
measurement................................................................. 9
7.2.
Using an H02(F) head with an NC03B nozzle station .. 10
8.
Troubleshooting errors that occur during hybrid
calibration measurement ................................ 11
8.1.
Errors when jig parts are not set on the stand ............... 11
8.2.
Stand mark vision processing errors ............................ 12
8.3.
Jig part vision processing errors .................................. 13
8.4.
Stand vacuum errors ................................................... 14
9.
Clearing errors in Accessory Software ........... 16
9.1.
Specify remote operation access authority .................. 16
9.2.
Clearing nozzle changeover errors from Accessory
Software ...................................................................... 17
10.
Reducing the time for hybrid calibration ......... 18
10.1.
Specifications and important points ............................. 18
10.2.
How to specify settings ................................................ 18
Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 3/18
1. Introduction
Hybrid calibration offset is a function that adds a correction for placement during actual
production based on placement deviation measured with a test part on a jig stand.
Function overview
·
Measurement is performed as part of autocalibration after exchanging heads.
·
The function uses a jig and test part placed inside the module. Placement is
performed and the placement deviation is measured by checking the actual position
of the test part.
·
The placement position (X, Y and Q-directions) is offset based on the measurements.
Advantages of hybrid calibration offset
·
The precision of the new function is higher than the previously used auto final offset.
2. Required items
The following items are required to perform hybrid calibration offset measurement.
Required optional units
·
φ1.3 jig nozzles for hybrid calibration
·
φ5.0 jig nozzles for hybrid calibration
·
Stand for hybrid calibration (including jig parts)