Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 9/18
7. Performing changeover
7.1. Performing changeover for hybrid calibration measurement
The following explains how to perform changeover for hybrid calibration
measurement.
Set the jig nozzles in the nozzle station as shown below.
NXT-2 operation panel NXT-3 operation panel
Jig nozzles that can be used (nozzles IDs are given)
Head type
Machine condition
H01,
H02(F)
G04(F)
H12S,
H12HS,
H08
H12L
H04,
H04S(F
)
V12D,
H24
OF DX(S1) DX(R4) DX(R12)
φ5.0 jig nozzle for glass
jig parts
J11 J13 - - J17 - J21 J60 J39 -
φ1.3 jig nozzles for chip
jig parts
J12 J14 J16 J63 J18 J44 - J59 J41 J16
Ÿ Dedicated jig nozzles are required for hybrid calibration measurement. It is
necessary to combine these with the normal jig nozzles used for
autocalibration.
Ÿ The number of dedicated hybrid calibration jig nozzles does not depend on the
number of holders on the head. Instead, one nozzle is required for each of the
jig parts.

Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 10/18
7.2. Using an H02(F) head with an NC03B nozzle station
When using an H02 head with an NC03B nozzle station, the dedicated hybrid
calibration jig nozzles cannot be set at the same time as the normal autocalibration
jig nozzles, due to the number of sockets in the nozzle station. When the (two) hybrid
calibration jig nozzles plus the number of holders on the head being used is greater
than the number of sockets on the nozzle station, guidance for the positioning of jig
nozzles is performed in two stages - immediately before calibration that uses the
normal jig nozzles and immediately before hybrid calibration measurement.
Perform changeover
(normal jig nozzle positioning guidance)
Autocalibration is performed using
normal jig nozzles
Position normal jig nozzles
Hybrid calibration is performed using
hybrid calibration jig nozzles
Perform changeover
(hybrid calibration jig nozzle positioning
guidance)
Position hybrid calibration jig nozzles
Perform changeover if necessary
(positioning guidance for nozzles used in
production)
Position nozzles to be used in
production
Perform production

Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 11/18
8. Troubleshooting errors that occur during hybrid calibration
measurement
The following explains how to troubleshoot errors that may occur when using the
hybrid calibration offset measurement function.
8.1. Errors when jig parts are not set on the stand
The presence of jig parts in the part pockets of the stand is checked by the mark
camera before measurement begins. An error occurs if parts cannot be detected.
For this error, because guidance is displayed to check whether jig parts are
actually set in the part pockets of the stand, the same error clearance guidance is
displayed as for when an emergency stop occurs during measurement (for an
unrelated reason such as the emergency stop button being pushed).
NXT-2 operation panel NXT-3 operation panel
1. Push the OK button (press the pull out module pictogram for the NXT-3) and pull
the module out.
2. Confirm that no jig parts remain inside the machine (such as on the stand or
the nozzle).
3. If any jig parts are found, remove them and set them in the part pockets on the
stand.
4. Push [OK] (press the step pictogram for the NXT-3) to tell the machine that
maintenance (setting the jig parts) is complete.
5. Returning the module completes the procedure for clearing the error. The
machine waits for the START button to be pushed.
6. Push the START button to start hybrid calibration measurement (regardless of
the condition before the error, measurement is performed for all holders).