Hybrid Calibration Offset Measurement and Correction Operation Manual.pdf - 第4页

H ybrid Cali bration Offset M easurement and Correction Operation Manual N XT V8.95 FUJI CORPORAT ION 4/18 3. Specifications and caut ion points Specifi cations and l i mitations when pe rforming hybri d calib ration of …

100%1 / 18
Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 3/18
1. Introduction
Hybrid calibration offset is a function that adds a correction for placement during actual
production based on placement deviation measured with a test part on a jig stand.
Function overview
·
Measurement is performed as part of autocalibration after exchanging heads.
·
The function uses a jig and test part placed inside the module. Placement is
performed and the placement deviation is measured by checking the actual position
of the test part.
·
The placement position (X, Y and Q-directions) is offset based on the measurements.
Advantages of hybrid calibration offset
·
The precision of the new function is higher than the previously used auto final offset.
2. Required items
The following items are required to perform hybrid calibration offset measurement.
Required optional units
·
φ1.3 jig nozzles for hybrid calibration
·
φ5.0 jig nozzles for hybrid calibration
·
Stand for hybrid calibration (including jig parts)
Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 4/18
3. Specifications and caution points
Specifications and limitations when performing hybrid calibration offset measurement
are as follows:
Head type Is this function supported?
H01 Yes
H02(F) Yes
G04(F)/G04Q(F) Yes
H12S/H12SQ Yes
H12HS/H12HSQ Yes
H12L Yes
V12 Yes
V12D Yes
H08/H08Q Yes
H08M Yes
H04/H04S(F) Yes
OF Yes
H24 Yes
DX Yes
Heads other than those above No
Module type Is this function supported?
M3(S), M6(S) No
M3-2(c), M6-2(c), M6-2SP Yes
M3-3(c) , M3-3S,
M6-3(c), M6-3L
Yes
Parts camera type Is this function supported?
Standard camera, P04CL,
BP04CL
Yes
Sidelight camera Yes (H01, H02, OF)
P03 camera Yes (H01, H02)
MP03 camera, MP03CL Yes (H01, H02, G04)
Hybrid Calibration Offset Measurement and Correction Operation Manual NXT V8.95
FUJI CORPORATION 5/18
MP05 camera, MP05CL Yes