3OM-1064-001 - 第113页
Error Code Display A Display B 0005-002 2-70 Tg0248-PM-ER 3. T rouble Shooting after Error Display 0C 03 01 ZB2-AXIS DA T A RECEIVED VERSION NUMBER FROM STEPPING MOTOR DRIVER W AS INCORRECT . (Cause 1) This is the device…

Error Code Display A Display B
0005-002 2-69 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0B 04 04 ZB1-AXIS COMMUNICATION TIME-OUT OCCURRED IN RECEIVING REPLY FROM
STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0B 04 03 ZB1-AXIS COMMUNICATION COMMUNICATION ERROR WAS DETECTED BY
STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

Error Code Display A Display B
0005-002 2-70 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0C 03 01 ZB2-AXIS DATA RECEIVED VERSION NUMBER FROM STEPPING
MOTOR DRIVER WAS INCORRECT.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 01 02 ZB2-AXIS ORIGIN ORIGIN WAS NOT DETECTED.
0C 01 03 ZB2-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
ZEROING IS REQUIRED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can't be re-started, contact our service personnel.
0C 01 10 ZB2-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
0C 01 01 ZB2-AXIS ORIGIN EXCITATION-MONITOR SIGNAL FROM STEPPING
MOTOR DRIVER WAS NOT DETECTED.
(Cause 1) This error occurs when the optical beam of the sensor is always kept in the “E / NR” or
the “E / R” condition during zeroing operation.
(E / NR: Light Emitted and Not Received, E / R: Light Emitted and Received)
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [RESET] button to cancel the error indication.
(2) Check whether the optical beam is always E / NR or E / R because of dirt on the sensor, or
whether the sensor is defective. How to check is to shine the optical beam of the sensor on a
piece of paper and check whether it is E / R or E / NR.
(3) Re-start.
(4) If the device still can’t be reset after the above procedures, contact our service personnel
because the sensor cable or sensor may be defective.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

Error Code Display A Display B
0005-002 2-71 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0C 04 02 ZB2-AXIS COMMUNICATION ERROR OCCURRED IN STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 04 01 ZB2-AXIS COMMUNICATION STEPPING MOTOR DRIVER COULD NOT EXECUTE
RECEIVED COMMAND.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 03 03 ZB2-AXIS DATA CHECK SUM ERROR ON RECEIVED DATA FROM
STEPPING MOTOR DRIVER WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 03 02 ZB2-AXIS DATA RECEIVED ADDRESS FROM STEPPING MOTOR
DRIVER WAS INCORRECT.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.