Error Code Display A Display B 0005-002 2-72 Tg0248-PM-ER 3. T rouble Shooting after Error Display 0C 04 04 ZB2-AXIS COMMUNICA TION TIME-OUT OCCURRED IN RECEIVING REPL Y FROM STEPPING MOTOR DRIVER. (Cause 1) This is the …

Error Code Display A Display B
0005-002 2-71 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0C 04 02 ZB2-AXIS COMMUNICATION ERROR OCCURRED IN STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 04 01 ZB2-AXIS COMMUNICATION STEPPING MOTOR DRIVER COULD NOT EXECUTE
RECEIVED COMMAND.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 03 03 ZB2-AXIS DATA CHECK SUM ERROR ON RECEIVED DATA FROM
STEPPING MOTOR DRIVER WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 03 02 ZB2-AXIS DATA RECEIVED ADDRESS FROM STEPPING MOTOR
DRIVER WAS INCORRECT.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

Error Code Display A Display B
0005-002 2-72 Tg0248-PM-ER
3. Trouble Shooting after Error Display
0C 04 04 ZB2-AXIS COMMUNICATION TIME-OUT OCCURRED IN RECEIVING REPLY FROM
STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0C 04 03 ZB2-AXIS COMMUNICATION COMMUNICATION ERROR WAS DETECTED BY
STEPPING MOTOR DRIVER.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

(Cause 1) Is the original position deviated?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Re-adjust the original position.
(2) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
3. Trouble Shooting after Error Display
0005-002 2-73 Tg0248-PM-ER
0D 01 04 BPC-AXIS ORIGIN ENCODER ORIGIN WAS DETECTED AT POINT OUT
OF ORIGIN (SLIDE).
0D 01 03 BPC-AXIS ORIGIN ORIGIN SENSOR (SLIDE) AND / OR LIMIT SENSOR
(−) MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0D 01 02 BPC-AXIS ORIGIN ORIGIN (SLIDE) WAS NOT DETECTED.
;BPH163 E / R
(Cause 1) The sensor may be defective.
(Cause 2) The cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel because a sensor or sensor
cable replacement might be required.
0D 01 01 BPC-AXIS ORIGIN ENCODER ORIGIN WAS NOT DETECTED.
(Cause 1) Motor encoder section may be defective.
(Cause 2) Encoder cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Turn off the power and check for loose connections between the sections of the motor and
signal cable.
(2) Re-start.
(3) If the device can’t be reset even after the above check, contact our service personnel because
the signal cable may be broken or the motor defective.