3OM-1064-001 - 第149页
0005-002 2-94 Tg0248-PM-ER Error Code Display A Display B 3. T rouble Shooting after Error Display 62 03 01 P-CONVEYOR OVERTIME P .C.B. ON P-CONVEYOR WAS ABLE TO MOVE T O ITS OUTLET . 62 03 02 P-CONVEYOR OVERTIME P .C.B.…

P.C.B. FROM EL-CONVEYOR WAS NOT RECEIVED.
0005-002 2-93 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
62 02 01 L-CONVEYOR OVERTIME
P.C.B. FROM INP. MACHINE WAS NOT RECEIVED.
62 02 02 L-CONVEYOR OVERTIME P.C.B. TO OUTPUT MACHINE WAS NOT TRANS-
FERRED.
62 02 03 L-CONVEYOR OVERTIME
P.C.B. ON L-CONVEYOR WAS NOT ABLE TO MOVE
TO ITS OUTLET.
62 02 05 L-CONVEYOR OVERTIME P.C.B. FROM P-CONVEYOR WAS NOT RECEIVED.
(Cause 1) A P.C.B. may be caught on the conveyor.
(Cause 2) The conveyor width may be maladjusted.
(Cause 3) The P.C.B. size may be larger than the specified size.
(Cause 4) The time indicated by the conveyor timer may be incorrect.
(Cause 5) A P.C.B. may have been removed during the P.C.B. feeding.
(Reset Procedure in the case of Causes 1, 2, 3, 4 and 5)
Reset Procedure
(1) Remove the caught P.C.B.
(2) Re-start.
(3) If the device can’t be re-started, contact our sales personnel because the sensor cable or
sensor may be defective.
62 02 04 L-CONVEYOR OVERTIME

0005-002 2-94 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
62 03 01 P-CONVEYOR OVERTIME P.C.B. ON P-CONVEYOR WAS ABLE TO MOVE TO
ITS OUTLET.
62 03 02 P-CONVEYOR OVERTIME P.C.B. FROM L-CONVEYOR WAS NOT RECEIVED.
62 03 03 P-CONVEYOR OVERTIME P.C.B. FROM R-CONVEYOR WAS NOT RECEIVED.
62 03 04 P-CONVEYOR OVERTIME THE L-P.C.B. STOPPER WAS NOT COMPLETELY
SENT BY A SET TIME.
62 03 05 P-CONVEYOR OVERTIME THE R-P.C.B. STOPPER WAS NOT COMPLETELY
SENT BY A SET TIME.
(Cause 1) A P.C.B. may be caught on the conveyor.
(Cause 2) The conveyor width may be maladjusted.
(Cause 3) The P.C.B. size may be larger than the specified size.
(Cause 4) The time indicated by the conveyor timer may be incorrect.
(Cause 5) A P.C.B. may have been removed during the P.C.B. feeding.
(Reset Procedure in the case of Causes 1, 2, 3, 4 and 5)
Reset Procedure
(1) Remove the caught P.C.B.
(2) Re-start.
(3) If the device can’t be re-started, contact our sales personnel because the sensor cable or
sensor may be defective.

P.C.B. FROM ER-CONVEYOR WAS NOT RECEIVED.62 04 04 R-CONVEYOR OVERTIME
(Cause 1) A P.C.B. may be caught on the conveyor.
(Cause 2) The conveyor width may be maladjusted.
(Cause 3) The P.C.B. size may be larger than the specified size.
(Cause 4) The time indicated by the conveyor timer may be incorrect.
(Cause 5) A P.C.B. may have been removed during the P.C.B. feeding.
(Reset Procedure in the case of Causes 1, 2, 3, 4 and 5)
Reset Procedure
(1) Remove the caught P.C.B.
(2) Re-start.
(3) If the device can’t be re-started, contact our sales personnel because the sensor cable or
sensor may be defective.
0005-002 2-95 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
62 04 05 R-CONVEYOR OVERTIME P.C.B. FROM P-CONVEYOR WAS NOT RECEIVED.
62 04 03 R-CONVEYOR OVERTIME P.C.B. ON R-CONVEYOR WAS NOT ABLE TO MOVE
TO ITS OUTLET.
62 04 01 R-CONVEYOR OVERTIME
62 04 02 R-CONVEYOR OVERTIME
P.C.B. FROM INP. MACHINE WAS NOT RECEIVED.
P.C.B. TO OUTPUT MACHINE WAS NOT TRANS-
FERRED.