0009-001 2-113-1 Tg0248-PM-ER Error Code Display A Display B 6C 01 0D ILLEGAL OPERA TION (Cause 1) This is the device’ s self-diagnostic message. (Reset Procedure in the case of Cause 1) Reset Procedure (1) Press the [CL…

0009-003 2-113 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6C 01 0A ILLEGAL OPERATION
INTERLOCK BYPASS SW WAS SWITCHED DURING MA-
CHINE OPERATION IN OPERATION PANEL LOCK STATE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Switch interlock bypass to off position.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6C 01 09 ILLEGAL OPERATION INTERLOCK BYPASS SW WAS SWITCHED
DURING MACHINE OPERATION.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Switch interlock bypass to off position.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6C 01 08 ILLEGAL OPERATION OPERATION SW ON INACTIVE PANEL WAS
SWITCHED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Set the [OPERATION/SET UP] switch to the “OPERATION” mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6C 01 07 ILLEGAL OPERATION OPERATION SW WAS SWITCHED IN LOAD POWER
SHUT-OFF STATE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Set the [OPERATION/SET UP] switch to the “OPERATION” mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.

0009-001 2-113-1 Tg0248-PM-ER
Error Code Display A Display B
6C 01 0D ILLEGAL OPERATION
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
6C 01 0C ILLEGAL OPERATION
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
6C 01 0B ILLEGAL OPERATION
INTERLOCK BYPASS SW WAS SWITCHED DURING MA-
CHINE OPERATION IN LOAD POWER SHUT-OFF STATE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Switch interlock bypass to off position.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
3. Trouble Shooting after Error Display

0103-003 2-114 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6C 02 02 FEEDER NOT READY FEEDER CARRIAGE [B] IS IN NOT READY MODE.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [READY [B]] button to set feeder carriage [B] in ready mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can't be re-started, contact our service personnel.
6C 02 01 FEEDER NOT READY FEEDER CARRIAGE [A] IS IN NOT READY MODE.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [READY [A]] button to set feeder carriage [A] in ready mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can't be re-started, contact our service personnel.