3OM-1064-001 - 第175页

0103-001 2-114-1 Tg0248-PM-ER Error Code Display A Display B 3. T rouble Shooting after Error Display 6C 03 01 NO CONTINUOUS ST ARTING DISABLES CONTINUOUS ST ARTING OF PLACEMENT OPERA TION FROM THE MIDDLE STEPS.(ENABLE W…

100%1 / 308
0103-003 2-114 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6C 02 02 FEEDER NOT READY FEEDER CARRIAGE [B] IS IN NOT READY MODE.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [READY [B]] button to set feeder carriage [B] in ready mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can't be re-started, contact our service personnel.
6C 02 01 FEEDER NOT READY FEEDER CARRIAGE [A] IS IN NOT READY MODE.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [READY [A]] button to set feeder carriage [A] in ready mode.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can't be re-started, contact our service personnel.
0103-001 2-114-1 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6C 03 01 NO CONTINUOUS STARTING
DISABLES CONTINUOUS STARTING OF PLACEMENT OPERATION
FROM THE MIDDLE STEPS.(ENABLE WARM START FUNCTION)
(Cause 1) Self-Diagnostics Error Message
When the normal procedure is followed to re-start the machine, the P.C.B. in the middle
of process is discharged to the output machine, producing a defective P.C.B. Follow the
remedial procedure (described later) to set the machine to the normal condition and re-
start the machine.
Example of “ERROR” Display (NO CONTINUOUS STARTING)
(NEXT PAGE)
0103-001 2-114-2 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Follow the steps below to reset the machine to the normal condition.
(2) When the [RESET] botton is pressed, the following display appears on the screen.
(3) Press the [WARM START] button.
The following “WARM START” display appears. After zeroing all the devices, perform the
warm start operation to complete the unfinished P.C.B.
Refer to “4.3 Warm Start of Section 3 in Volume 1” for details.