3OM-1064-001 - 第185页
0005-002 2-123 Tg0248-PM-ER Error Code Display A Display B 3. T rouble Shooting after Error Display 6D 0C 02 OFFSET TEACHING BRIGHTNESS XXXXXXXX TEACHING RESUL T IS OUT OF T OLERANCE. (Cause 1) This is the device’ s self…

0005-002 2-122 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6D 0B 07 TEACH COMP. RECOG.
BRIGHTNESS XXXXXXXX
TEACHING RESULT IS OUT OF TOLERANCE.
[HEAD LIGHT]
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not turn on light at unit adjustment.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6D 0B 04 TEACH COMP. RECOG.
BRIGHTNESS XXXXXXXX
TEACHING RESULT IS OUT OF TOLERANCE.
[FRONT LIGHT (MIDDLE)]
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not there is foreign substance at the lighting section.
Check whether or not turn on light at unit adjustment.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6D 0B 05 TEACH COMP. RECOG.
BRIGHTNESS XXXXXXXX
TEACHING RESULT IS OUT OF TOLERANCE.
[FRONT LIGHT (DOWN)]
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not there is foreign substance at the lighting section.
Check whether or not turn on light at unit adjustment.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
TEACHING RESULT IS OUT OF TOLERANCE.
[BACK LIGHT]
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not there is foreign substance at the lighting section.
Check whether or not turn on light at unit adjustment.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6D 0B 06 TEACH COMP. RECOG.
BRIGHTNESS XXXXXXXX
Note: Refer to “Section 4 Recognition Error Codes”.

0005-002 2-123 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6D 0C 02 OFFSET TEACHING
BRIGHTNESS XXXXXXXX
TEACHING RESULT IS OUT OF TOLERANCE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not there is foreign substance at the lighting section.
Check whether or not turn on light at unit adjustment.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
6D 0C 01 OFFSET TEACHING
BRIGHTNESS XXXXXXXX
RECOGNITION ERROR OCCURRED DURING
TEACHING.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
6D 0D 02
OFFSET TEACHING HEAD OFFSET
(GET BOTH IMAGE) XXXXXXXX
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Check whether or not turn on light at unit adjustment.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
CHECKER MARK NOT RECOGNIZED BETWEEN
COMPONENT RECOGNITION CAMERA.
6D 0D 01
OFFSET TEACHING HEAD OFFSET
(GET BOTH IMAGE) XXXXXXXX
JIG COMPONENT NOT RECOGNIZED THROUGH
COMPONENT RECOGNITION CAMERA.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Note: Refer to “Section 4 Recognition Error Codes”.

(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Remove component from component reject cup [B].
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
0005-002 2-124 Tg0248-PM-ER
Error Code Display A Display B
3. Trouble Shooting after Error Display
6E 02 01 COMPONENT REJECT
CUP [B]
COMPONENT REJECT CUP [B] BECAME FULL.
;CC(B)-BPH044
6E 01 01 COMPONENT REJECT
CUP [A]
COMPONENT REJECT CUP [A] BECAME FULL.
;CC(A)-BPH044
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Remove component from component reject cup [A].
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.