3OM-1064-001 - 第215页

3. Control-to-Control Communication Error Code and List of Error Messages 0005-002 4-19 Tg0248-PM-ER Error Code Display A Display B 10410000 IMPLEMENTING THE NOZZLE RECOGNITION “CAMERA NO.” EXCEEDS THE RANGE OF SETTING. …

100%1 / 308
3. Control-to-Control Communication Error Code and List of Error Messages
0005-002 4-18 Tg0248-PM-ER
Error Code Display A Display B
10367100 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“BALL OFFSET CHECK” EXCEEDS THE RANGE OF
SETTING.
10367101 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“BALL OFFSET TOLERANCE” EXCEEDS THE RANGE
OF SETTING.
10368000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“NUMBER OF LEAD GROUPS” EXCEEDS THE RANGE
OF SETTING.
10368001 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“LEAD TYPE NO.” EXCEEDS THE RANGE OF SETTING.
10368002 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“NUMBER OF LEAD TYPES” EXCEEDS THE RANGE OF
SETTING.
10368003 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“LEAD MODE” EXCEEDS THE RANGE OF SETTING.
10369000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“NUMBER OF EDGES” EXCEEDS THE RANGE OF
SETTING.
“EDGE START POSITION” EXCEEDS THE RANGE OF
SETTING.
10369002 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“EDGE DIRECTION” EXCEEDS THE RANGE OF
SETTING.
10369003 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“EDGE WIDTH” EXCEEDS THE RANGE OF SETTING.
10369001 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
10400001 TEACHING THE CAMERA
MAGNIFICATION
“GRID PITCH” EXCEEDS THE RANGE OF SETTING.
10400000 TEACHING THE CAMERA
MAGNIFICATION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10367013 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“INSPECTION POSITION” EXCEEDS THE RANGE OF
SETTING.
“MISSING BALL DETECTION MODE” EXCEEDS THE
RANGE OF SETTING.
10367014 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
3. Control-to-Control Communication Error Code and List of Error Messages
0005-002 4-19 Tg0248-PM-ER
Error Code Display A Display B
10410000 IMPLEMENTING THE NOZZLE
RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10410001 IMPLEMENTING THE NOZZLE
RECOGNITION
“NOZZLE ID” EXCEEDS THE RANGE OF SETTING.
10420001 IMPLEMENTING THE P.E.C.
RECOGNITION
“MARK NO.” EXCEEDS THE RANGE OF SETTING.
10420000 IMPLEMENTING THE P.E.C.
RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10420002 IMPLEMENTING THE P.E.C.
RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF
SETTING.
10420003 IMPLEMENTING THE P.E.C.
RECOGNITION
“MARK POSITION” EXCEEDS THE RANGE OF
SETTING.
10420004 IMPLEMENTING THE P.E.C.
RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
10410002 IMPLEMENTING THE NOZZLE
RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10410003 IMPLEMENTING THE NOZZLE
RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
3. Control-to-Control Communication Error Code and List of Error Messages
0005-002 4-20 Tg0248-PM-ER
Error Code Display A Display B
10430005 IMPLEMENTING THE COM-
PONENT RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10430006 IMPLEMENTING THE COM-
PONENT RECOGNITION
“PLACEMENT ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10430007 IMPLEMENTING THE COM-
PONENT RECOGNITION
“NUMBER OF MOVEMENT” EXCEEDS THE RANGE OF
SETTING.
10430008 IMPLEMENTING THE COM-
PONENT RECOGNITION
“MOVEMENT ID” EXCEEDS THE RANGE OF SETTING.
10430009 IMPLEMENTING THE COM-
PONENT RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
10440001 IMPLEMENTING THE CHAR-
ACTER RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10440000 IMPLEMENTING THE CHAR-
ACTER RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10440002 IMPLEMENTING THE CHAR-
ACTER RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
10430001 IMPLEMENTING THE COM-
PONENT RECOGNITION
“COMPONENT NO.” EXCEEDS THE RANGE OF
SETTING.
10430002 IMPLEMENTING THE COM-
PONENT RECOGNITION
“HEAD NO.” EXCEEDS THE RANGE OF SETTING.
10430003 IMPLEMENTING THE COM-
PONENT RECOGNITION
“NOZZLE ID” EXCEEDS THE RANGE OF SETTING.
10430004 IMPLEMENTING THE COM-
PONENT RECOGNITION
“NOZZLE POSITION” EXCEEDS THE RANGE OF
SETTING.
10430000 IMPLEMENTING THE COM-
PONENT RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.