3OM-1064-001 - 第216页
3. Control-to-Control Communication Error Code and List of Error Messages 0005-002 4-20 Tg0248-PM-ER Error Code Display A Display B 10430005 IMPLEMENTING THE COM- PONENT RECOGNITION “DESTINA TED ANGLE” EXCEEDS THE RANGE …

3. Control-to-Control Communication Error Code and List of Error Messages
0005-002 4-19 Tg0248-PM-ER
Error Code Display A Display B
10410000 IMPLEMENTING THE NOZZLE
RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10410001 IMPLEMENTING THE NOZZLE
RECOGNITION
“NOZZLE ID” EXCEEDS THE RANGE OF SETTING.
10420001 IMPLEMENTING THE P.E.C.
RECOGNITION
“MARK NO.” EXCEEDS THE RANGE OF SETTING.
10420000 IMPLEMENTING THE P.E.C.
RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10420002 IMPLEMENTING THE P.E.C.
RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF
SETTING.
10420003 IMPLEMENTING THE P.E.C.
RECOGNITION
“MARK POSITION” EXCEEDS THE RANGE OF
SETTING.
10420004 IMPLEMENTING THE P.E.C.
RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
10410002 IMPLEMENTING THE NOZZLE
RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10410003 IMPLEMENTING THE NOZZLE
RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

3. Control-to-Control Communication Error Code and List of Error Messages
0005-002 4-20 Tg0248-PM-ER
Error Code Display A Display B
10430005 IMPLEMENTING THE COM-
PONENT RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10430006 IMPLEMENTING THE COM-
PONENT RECOGNITION
“PLACEMENT ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10430007 IMPLEMENTING THE COM-
PONENT RECOGNITION
“NUMBER OF MOVEMENT” EXCEEDS THE RANGE OF
SETTING.
10430008 IMPLEMENTING THE COM-
PONENT RECOGNITION
“MOVEMENT ID” EXCEEDS THE RANGE OF SETTING.
10430009 IMPLEMENTING THE COM-
PONENT RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
10440001 IMPLEMENTING THE CHAR-
ACTER RECOGNITION
“DESTINATED ANGLE” EXCEEDS THE RANGE OF SET-
TING.
10440000 IMPLEMENTING THE CHAR-
ACTER RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10440002 IMPLEMENTING THE CHAR-
ACTER RECOGNITION
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
10430001 IMPLEMENTING THE COM-
PONENT RECOGNITION
“COMPONENT NO.” EXCEEDS THE RANGE OF
SETTING.
10430002 IMPLEMENTING THE COM-
PONENT RECOGNITION
“HEAD NO.” EXCEEDS THE RANGE OF SETTING.
10430003 IMPLEMENTING THE COM-
PONENT RECOGNITION
“NOZZLE ID” EXCEEDS THE RANGE OF SETTING.
10430004 IMPLEMENTING THE COM-
PONENT RECOGNITION
“NOZZLE POSITION” EXCEEDS THE RANGE OF
SETTING.
10430000 IMPLEMENTING THE COM-
PONENT RECOGNITION
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

3. Control-to-Control Communication Error Code and List of Error Messages
0005-002 4-21 Tg0248-PM-ER
Error Code Display A Display B
10450001 TEACHING THE CAMERA
GAIN / LEVEL
“HEAD NO.” EXCEEDS THE RANGE OF SETTING.
10450000 TEACHING THE CAMERA
GAIN / LEVEL
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10460000 TEACHING THE CAMERA
SHUTTER SPEED
“CAMERA NO.” EXCEEDS THE RANGE OF SETTING.
10460001 TEACHING THE CAMERA
SHUTTER SPEED
“HEAD NO.” EXCEEDS THE RANGE OF SETTING.
10460002 TEACHING THE CAMERA
SHUTTER SPEED
“LEVEL” EXCEEDS THE RANGE OF SETTING.
10460003 TEACHING THE CAMERA
SHUTTER SPEED
“RECOGNITION METHOD” EXCEEDS THE RANGE OF
SETTING.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.