3OM-1064-001 - 第223页

3. Control-to-Control Communication Error Code and List of Error Messages 0009-003 4-27 Tg0248-PM-ER Error Code Display A Display B 1 1360001 TRANSFERRING THE COM- PONENT RECOGNITION DA T A UNABAILABLE RECOGNITION IN CAM…

100%1 / 308
3. Control-to-Control Communication Error Code and List of Error Messages
0005-002 4-26 Tg0248-PM-ER
Error Code Display A Display B
11350000 TRANSFERRING THE P.E.C.
RECOGNITION DATA
UNAVAILABLE FIDUCIAL MARK CODE WAS SET.
11350001 TRANSFERRING THE P.E.C.
RECOGNITION DATA
“MARK SIZE D2” IS TOO BIG, COMPARED WITH “D1”.
11350004 TRANSFERRING THE P.E.C.
RECOGNITION DATA
“WINDOW SIZE” IS SMALLER THAN “MARK SIZE”.
11350005 TRANSFERRING THE P.E.C.
RECOGNITION DATA
“MARK SIZE D2” IS NOT SET.
11350006 TRANSFERRING THE P.E.C.
RECOGNITION DATA
“MARK SIZE D3” IS NOT SET.
11350002 TRANSFERRING THE P.E.C.
RECOGNITION DATA
“MARK SIZE D3” IS TOO BIG, COMPARED WITH “D1”.
11350003 TRANSFERRING THE P.E.C.
RECOGNITION DATA
“MARK SIZE D2” IS TOO BIG, COMPARED WITH “D3”.
11300000 TRANSFERRING THE CAM-
ERA MAGNIFICATION DATA
THE TRANSFERRED MAGNIFICATION DOES NOT
MEET THE SPECIFICATIONS OF THE MACHINE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
3. Control-to-Control Communication Error Code and List of Error Messages
0009-003 4-27 Tg0248-PM-ER
Error Code Display A Display B
11360001 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
UNABAILABLE RECOGNITION IN CAMERA WITH MA-
CHINE BECAUSE “OUTWARD LENGTH” IS BIG.
11360002 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
11360003 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
UNAVAILABLE RECOGNITION IN CAMERA WITH MA-
CHINE BECAUSE “LEAD PITCH” IS SMALL.
11360004 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
UNAVAILABLE RECOGNITION IN CAMERA WITH MA-
CHINE BECAUSE “BALL DIAMETER” IS SMALL.
11360000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
UNABAILABLE RECOGNITION IN CAMERA WITH MA-
CHINE BECAUSE “OUTWARD LENGTH” IS SMALL.
11360005 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
UNAVAILABLE RECOGNITION IN CAMERA WITH MA-
CHINE BECAUSE “BALL PITCH” IS SMALL.
11360006 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
ALL CAMERAS ARE CANCELED DUE TO THE PARAM-
ETER SET FOR “VIEW RANGE SET”.
UNAVAILABLE RECOGNITION IN CAMERA WITH MA-
CHINE BECAUSE “LEAD WIDTH” IS SMALL.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
11360007 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
POLARITY CANNOT BE DETECTED BECAUSE
“OUTWARD LENGTH” IS BIG.
11360008 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“FLUX DIP & MOUNT” IS SET AS MOUNT MODE BUT
THERE IS NOT MIN VIEW CAMERA WITH MACHINE.
A PARAMETER OTHER THAN “90°INCR” IS SET AS “LIN-
EAR EDGE DIRECTION”.
3. Control-to-Control Communication Error Code and List of Error Messages
0009-003 4-28 Tg0248-PM-ER
Error Code Display A Display B
11364000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“DISABLE” IS SET FOR ALL CORNER FORMS 1 TO 4.
11364001 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
A PARAMETER OTHER THAN “STRAIGHT” IS SET FOR
ALL EDGE FORMS 1 TO 4.
11365000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“LEAD WIDTH” IS LARGER THAN “LEAD PITCH”.
11365001 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“MISSING LEAD START” IS LARGER THAN “# OF LEADS
+1”.
11365002 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
11365003 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
THE PARAMETER SELECTED FOR “RECOGNITION
LIGHTING MODE” DOES NOT CONFORM TO THE PA-
RAMETER SET FOR “LEAD FORM”.
11365004 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
11365005 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“LEAD FULL LENGTH” IS NOT SET.
11367000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“BALL DIAMETER” IS LARGER THAN “BALL PITCH”.
11367001 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“MISSING BALL START” IS LARGER THAN “# OF BALL”.
11368000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
AN UNREGISTERED LEAD TYPE NO. IS SELECTED.
11368001 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
A PARAMETER OTHER THAN “90°INCR” IS SET AS
“LEAD GROUP DIRECTION”.
11369000 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“LEAD LENGTH” IS LARGER THAN “LEAD FULL
LENGTH”.
“LEAD LENGTH” IS NOT SET.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
11367002 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“INSPECTION RANGE” IS OUT OF COMPONENT SIZE.
11367003 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“# OF BALLS” IS TOO SMALL.
11367004 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
THOSE BALLS OVERLAPPED.
11367006 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“# OF LEADS” IS TOO SMALL.
11367007 TRANSFERRING THE COM-
PONENT RECOGNITION DATA
“# OF LEADS” IS TOO MANY.