3OM-1064-001 - 第250页
Note : The second digit from the last one of the error code represents Electrical Contact 1, 2, or 3. The third digit from the last one of the error code represents Electrical Contact Position 0, 1, 2, or 3. 0: Upper Sid…

0103-003 4-48 Tg0248-PM-ER
Error Code Display A Display B
5. Component Recognition Error Code and List of Error Messages
2041A260 ELECTRICAL CONTACT (LEFT)
to 269 RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-LEFT) OF ELECTRICAL CONTACT 2 IS
UNABLE RECOGNITION.
EDGE (LOWER-RIGHT) OF ELECTRICAL CONTACT 2
IS UNABLE RECOGNITION.
2041A290 ELECTRICAL CONTACT (LEFT)
to 299 RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-RIGHT) OF ELECTRICAL CONTACT 2
IS UNABLE RECOGNITION.
2041A270 ELECTRICAL CONTACT (LEFT)
to 279 RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (LOWER-LEFT) OF ELECTRICAL CONTACT 2
IS UNABLE RECOGNITION.
2041A300 ELECTRICAL CONTACT (LEFT)
to 309 RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING CORNER
RECOGNITION OF ELECTRICAL CONTACT 3.
2041A310 ELECTRICAL CONTACT (LEFT)
to 319 RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-LEFT) OF ELECTRICAL CONTACT
3 IS UNABLE RECOGNITION.
2041A280 ELECTRICAL CONTACT (LEFT)
to 289 RECOGNITION ERROR
Note: A represents “2” or “3”.
Note: The second digit from the last one of the error code represents Electrical Contact 1, 2, or 3.
The third digit from the last one of the error code represents Electrical Contact Position 0,
1, 2, or 3.
0: Upper Side 1: Left Side 2: Lower Side 3: Right Side
(Cause 1) Wrong parameters (electrical contact data) are set in the component library data for the
selected component.
(Cause 2) Is there any inconsistent reflection at the electrical contact corner or edge?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Check the selected component and the electrical contact data in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
(Reset Procedure in the case of Cause 2)
Reset Procedure
(1) In this case, change the lighting mode to “MANUAL (FRONT LIGHTING)” and perform the
recognition with much brighter light.

Note: The second digit from the last one of the error code represents Electrical Contact 1, 2, or 3.
The third digit from the last one of the error code represents Electrical Contact Position 0,
1, 2, or 3.
0: Upper Side 1: Left Side 2: Lower Side 3: Right Side
(Cause 1) Wrong parameters (electrical contact data) are set in the component library data for the
selected component.
(Cause 2) Is there any inconsistent reflection at the electrical contact corner or edge?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Check the selected component and the electrical contact data in the component library data.
(2) If wrong parameters are set in the component library data, correct them.
(Reset Procedure in the case of Cause 2)
Reset Procedure
(1) In this case, change the lighting mode to “MANUAL (FRONT LIGHTING)” and perform the
recognition with much brighter light.
EDGE (UPPER-RIGHT) OF ELECTRICAL CONTACT 3
IS UNABLE RECOGNITION.
0103-001 4-48-1 Tg0248-PM-ER
Error Code Display A Display B
2041A370 ELECTRICAL CONTACT (LEFT)
to 379 RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (LOWER-LEFT) OF ELECTRICAL CONTACT 3
IS UNABLE RECOGNITION.
2041A380 ELECTRICAL CONTACT (LEFT)
to 389 RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (LOWER-RIGHT) OF ELECTRICAL CONTACT 3
IS UNABLE RECOGNITION.
2041A320 ELECTRICAL CONTACT (LEFT)
to 329 RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-LEFT) OF ELECTRICAL CONTACT
3 IS UNABLE RECOGNITION.
2041A390 ELECTRICAL CONTACT (LEFT)
to 399 RECOGNITION ERROR
Note: A represents “2” or “3”.
2041A330 ELECTRICAL CONTACT (LEFT)
to 339 RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-RIGHT) OF ELECTRICAL CON-
TACT 3 IS UNABLE RECOGNITION.
2041A340 ELECTRICAL CONTACT (LEFT)
to 349 RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-RIGHT) OF ELECTRICAL CON-
TACT 3 IS UNABLE RECOGNITION.
2041A350 ELECTRICAL CONTACT (LEFT)
to 359 RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING EDGE
RECOGNITION OF ELECTRICAL CONTACT 3.
2041A360 ELECTRICAL CONTACT (LEFT)
to 369 RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-LEFT) OF ELECTRICAL CONTACT 3 IS
UNABLE RECOGNITION.
5. Component Recognition Error Code and List of Error Messages

CORNER (UPPER-RIGHT) OF ELECTRICAL CON-
TACT 2 IS UNABLE RECOGNITION.
0103-003 4-49 Tg0248-PM-ER
Error Code Display A Display B
INTERNAL ERROR OCCURRED DURING EDGE
RECOGNITION OF ELECTRICAL CONTACT 2.
5. Component Recognition Error Code and List of Error Messages
EDGE (LOWER-RIGHT) OF ELECTRICAL CONTACT 1
IS UNABLE RECOGNITION.
2042A190 ELECTRICAL CONTACT (LOW-
to 199 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-RIGHT) OF ELECTRICAL CONTACT 1
IS UNABLE RECOGNITION.
2042A200 ELECTRICAL CONTACT (LOW-
to 209 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING CORNER
RECOGNITION OF ELECTRICAL CONTACT 2.
2042A220 ELECTRICAL CONTACT (LOW-
to 229 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-LEFT) OF ELECTRICAL CONTACT
2 IS UNABLE RECOGNITION.
2042A230 ELECTRICAL CONTACT (LOW-
to 239 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-RIGHT) OF ELECTRICAL CON-
TACT 2 IS UNABLE RECOGNITION.
2042A210 ELECTRICAL CONTACT (LOW-
to 219 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-LEFT) OF ELECTRICAL CONTACT
2 IS UNABLE RECOGNITION.
2042A240 ELECTRICAL CONTACT (LOW-
to 249 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
2042A180 ELECTRICAL CONTACT (LOW-
to 189 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
2042A250 ELECTRICAL CONTACT (LOW-
to 259 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
(NEXT PAGE)
2042A140 ELECTRICAL CONTACT (LOW-
to 149 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-RIGHT) OF ELECTRICAL CON-
TACT 1 IS UNABLE RECOGNITION.
2042A150 ELECTRICAL CONTACT (LOW-
to 159 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING EDGE
RECOGNITION OF ELECTRICAL CONTACT 1.
2042A010 ELECTRICAL CONTACT (LOW-
to 049 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
NOZZLE PROTRUSION PRESENTS ON SOME
ELECT-RICAL CONTACTS.
2042A170 ELECTRICAL CONTACT (LOW-
to 179 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (LOWER-LEFT) OF ELECTRICAL CONTACT 1
IS UNABLE RECOGNITION.
2042A160 ELECTRICAL CONTACT (LOW-
to 169 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
EDGE (UPPER-LEFT) OF ELECTRICAL CONTACT 1 IS
UNABLE RECOGNITION.
2042A100 ELECTRICAL CONTACT (LOW-
to 109 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
INTERNAL ERROR OCCURRED DURING CORNER
RECOGNITION OF ELECTRICAL CONTACT 1.
2042A110 ELECTRICAL CONTACT (LOW-
to 119 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (UPPER-LEFT) OF ELECTRICAL CONTACT
1 IS UNABLE RECOGNITION.
2042A120 ELECTRICAL CONTACT (LOW-
to 129 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-LEFT) OF ELECTRICAL CONTACT
1 IS UNABLE RECOGNITION.
2042A130 ELECTRICAL CONTACT (LOW-
to 139 ER) RECOGNITION ERROR
Note: A represents “2” or “3”.
CORNER (LOWER-RIGHT) OF ELECTRICAL CON-
TACT 1 IS UNABLE RECOGNITION.