3OM-1064-001 - 第270页

0103-001 4-54-3 Tg0248-PM-ER 5. Component Recognition Error Code and List of Error Messages Error Code Display A Display B 20672085 COMPONENT DETECTION ERROR COMPONENT OUTW ARD LENGTH Y W AS OUT OF TOLERANCE. 20672084 CO…

100%1 / 308
0103-001 4-54-2 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672081 COMPONENT DETECTION
ERROR
CONTRAST BETWEEN COMPONENT AND BACK-
GROUND IS TOO LOW.
20672082 COMPONENT DETECTION
ERROR
THE OUTLINE CANNOT BE DETECTED AD-
EQUATELY.
20672083 COMPONENT DETECTION
ERROR
EDGE OF ELECTRICAL CONTACT NOT FOUND.
(Cause 1) The lighting is not ON.
(Cause 2) The camera shutter speed is not suitable.
(In normal cases, the speed should be "5.0 to 11.0 ms".)
(Cause 3) The gain and level of the camera are not suitable.
(In normal cases, the gain should be "160 to 190" and the level "0 to 10".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The lighting is not ON.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) No component is picked up.
(Cause 2) An improper parameter is set in the "X" or "Y" data box of the label "MOLD SIZE".
(Cause 3) The lighting is not ON.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
0103-001 4-54-3 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672085 COMPONENT DETECTION
ERROR
COMPONENT OUTWARD LENGTH Y WAS OUT OF
TOLERANCE.
20672084 COMPONENT DETECTION
ERROR
COMPONENT OUTWARD LENGTH X WAS OUT OF
TOLERANCE.
20672090 COMPONENT DETECTION
ERROR
RECOGNTION ABORTED BECAUSE OF IMPROPER
COMPONENT HANDLING.
20672086 COMPONENT DETECTION
ERROR
COMPONENT OUTLINE NOT FOUND.
(Cause 1) An improper parameter is set in the "X" or "Y" data box of the label "MOLD SIZE".
(Cause 2) Too small parameters are set in the "X" and "Y" data boxes of the label "MOLD SIZE
TOLERANCE".
The parameters set in the "X" and "Y" data boxes of the "MOLD SIZE TOLERANCE"
become valid when "MANUAL" is set in the "RECOG DATA SET" and "MOLD SIZE
TOLERANCE SET" data boxes.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The lighting is not ON.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
0103-001 4-54-4 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672094 COMPONENT DETECTION
ERROR
NOZZLE PROTRUSION OCCUPIES COMPONENT
OUTWARD LENGTH.
20672101 COMPONENT DETECTION
ERROR
CONTRAST BETWEEN COMPONENT AND BACK-
GROUND IS TOO LOW.
20672102 COMPONENT DETECTION
ERROR
THE DETECTED LEAD POSITION DOES NOT MATCH
THE POSITION DATA.
(Cause 1) The diameter of the selected nozzle is larger than the outline of the component.
(Cause 2) Improper parameters are set in the "X" and "Y" data boxes of the label "NOZZLE
OUTER SIZE" at the "NOZZLE TYPE DATA" display.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The lighting is not ON.
(Cause 2) The camera shutter speed is not suitable.
(In normal cases, the speed should be "5.0 to 11.0 ms".)
(Cause 3) The gain and level of the camera are not suitable.
(In normal cases, the gain should be "160 to 190" and the level "0 to 10".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) The component library data is not suitable.
(The data can be checked through component recognition test.)
(Cause 2) The component thickness is not suitable.
(This error may occur because the entire image (the image captured by the camera) of
the component is large or small.)
(Cause 3) The camera magnification is not suitable.
(When four cameras are individually used to perform component recognition tests on
the component and this type of error occurs in only one camera, the camera magnifica-
tion may be wrong.)
(NEXT PAGE)