3OM-1064-001 - 第280页
0103-001 4-55-4 Tg0248-PM-ER 5. Component Recognition Error Code and List of Error Messages Error Code Display A Display B 20672152 COMPONENT DETECTION ERROR CONTRAST BETWEEN COMPONENT AND BACK- GROUND IS TOO LOW . 20672…

0103-001 4-55-3 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672148 COMPONENT DETECTION
ERROR
LEAD POSITION (LEAD ARRAY DIRECTION) WAS
OUT OF TOLERANCE.
When "AUTO" is set in the "RECOG DATA SET" data box and in the "RECOG DATA" data box
+ "ENBL (AUTO)" in the "LEAD POS (LATL DIR) DETN" data box, The tolerance is automati-
cally set.
This error can be avoided by setting in the "RECOG DATA" data box + in the "RECOG DATA
SET" data box and "DISABLE" in the "LEAD POS (LATL DIR) DETN" data box.
When these parameters are set, no bent lead is detected.
(Cause 1) There is a bent lead.
(Cause 2) The lead width is not suitable.
(When the lead width tolerance is automatically set and a parameter smaller than the
actual width is set as the lead width, a smaller parameter (tolerance decreased as much
as the reduction of the lead width) is also set.)
(Cause 3) The component thickness and the camera magnification are not suitable.
(When an image larger or smaller than the actual component size (component data) is
captured, the closer to both ends of the lead group the leads are located, the greater the
positional deviation becomes and such leads are detected as "bent ones".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
Actual Component
Component Data

0103-001 4-55-4 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672152 COMPONENT DETECTION
ERROR
CONTRAST BETWEEN COMPONENT AND BACK-
GROUND IS TOO LOW.
20672153 COMPONENT DETECTION
ERROR
LEAD NOT FOUND.
(Cause 1) The lighting is not ON.
(Cause 2) The camera shutter speed is not suitable.
(In normal cases, the speed should be "5.0 to 11.0 ms".)
(Cause 3) The gain and level of the camera are not suitable.
(In normal cases, the gain should be "160 to 190" and the level "0 to 10".)
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) No component is picked up.
(Cause 2) A different component (small component, etc.) is picked up.
(Cause 3) The lighting is not ON.
(Reset Procedure in the case of Causes 1, 2 and 3)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.

0103-001 4-55-5 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672154 COMPONENT DETECTION
ERROR
THE LEADS CANNOT BE DETECTED ADEQUATELY.
20672171 COMPONENT DETECTION
ERROR
SOME BALLS CANNOT BE DETECTED.
20672163 COMPONENT DETECTION
ERROR
LEAD POSITION (LEAD LENGTH DIRECTION) WAS
OUT OF TOLERANCE.
(Cause 1) Any part (mold, etc.) other than the leads is as bright as the leads or brighter than the
leads.
(Cause 2) When much part other than the leads is as bright as the leads, the component may not
be recognized. In this case, set "CONNECTOR" in the "PACKAGE TYPE" data box
and perform the recognition.
(Cause 3) No component is picked up.
(Cause 4) The lighting is not ON.
(Reset Procedure in the case of Causes 1, 2, 3 and 4)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.