5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672241 COMPONENT DETECTION
ERROR
BALL POSITION WAS OUT OF TOLERANCE.
20672240 COMPONENT DETECTION
ERROR
POSITIONING ABORTED BECAUSE THE BALLS
CANNOT BE DETECTED ADEQUATELY.
(Cause 1) The pick-up position and the angle are shifted greatly.
(When the pick-up position and the angle are shifted greatly, this error may occur
because the balls are excluded from the inspected position, disabling the detection.)
(Cause 2) Wrong parameters are set in the "# OF ROWS", "# OF COLS", and "PITCH" data
boxes.
(This can be checked through component recognition test.)
(Cause 3) The component thickness and the camera magnification are not suitable.
(This error may occur because the entire image (the image captured by the camera) of
the component is large or small.)
(Cause 4) Dirt, etc., have adhered to the cover glass in the fixed lighting unit.
(This can be checked through the recognition monitor.)
(Reset Procedure in the case of Causes 1, 2, 3 and 4)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
0103-003 4-57 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672499 COMPONENT DETECTION
ERROR
LEAD POSITION (LEAD ARRAY DIRECTION) WAS
OUT OF TOLERANCE.
(Cause 1) There is a bend in the latitudinal direction of the lead.
(Cause 2) The size of the component is not correct.
(Cause 3) The following parameters are set wrong at the "CMPNT LIBRARY [SHAPE]" dis-
plays.
"MOLD SIZE X, Y"
"LEAD DATA" - "PITCH"
"EXTENDED SETTING" - "LEAD GROUP POSITION"
"COMPONENT THICKNESS t"
"LEAD GROUP DATA"
"COMPONENT THICKNESS t"
A wrong parameter is set in the "FOCUS ADJUSTMENT" data box at the "CMPNT
LIBRARY [CONTROL]" display.
Wrong parameters are set in the "LEAD POS (LATL DIR) DETN" and "LEAD POS
(LATL DIR) TOL" data boxes at the "CMPNT LIBRARY [RECOG]" display.
(Cause 4) The size of the nozzle is not correct.
(A wrong parameter is set in the "NOZZLE LENGTH" data box at the "NOZZLE
TYPE DATA" display for the selected nozzle.)
(Reset Procedure in the case of Causes 1, 2, 3 and 4)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) To handle the objective component as a good one although the data is correct but some of the
actual leads are bent, set "MANUAL" in the "RECOG DATA SET" data box and "ENBL
(MNL)" in the "LEAD POS (LATL DIR) DETN" data box to specify a proper value in the
"LEAD POS (LATL DIR) TOL" data box. (Change of Criteria)
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0103-003 4-58 Tg0248-PM-ER
5. Component Recognition Error Code and List of Error Messages
Error Code Display A Display B
20672666 COMPONENT DETECTION
ERROR
THE DETECTED # OF LEADS IS TOO SMALL AND
THE COMPONENT CANNOT BE LOCATED.
(Cause 1) The size of the component is not correct.
Wrong parameters are set as the extended data related to "# OF LEADS" of "LEAD
DATA" at the "CMPNT LIBRARY [SHAPE]" display.
[At least one side of the mold should have two or more leads. No parameters should be
set in the "# OF MISSING LEADS" data boxes at the "EXTENDED SETTING"
display.]
Wrong parameters are set in the "LEAD GROUP DATA" data fields at the "CMPNT
LIBRARY [SHAPE]" display.
[At least one side of the mold should have two or more leads. The leads should belong
to the same group and no parameters should be set in the "# OF MISSING LEADS"
data boxes at the "EXTENDED SETTING" display.]
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.