3OM-1064-001 - 第49页
(Cause 1) It may run away due to noise or overcurrent. (Cause 2) The sensor may be defective. (Reset Procedure in the case of Causes 1 and 2) Reset Procedure (1) Press the [CLEAR ALARM] key and the buzzer stops sounding.…

01 01 01 XA-AXIS ORIGIN ENCODER ORIGIN WAS NOT DETECTED.
01 01 02 XA-AXIS ORIGIN ORIGIN (SLIDE) WAS NOT DETECTED.
;C(A)-BPH024 E / R
Error Code Display A Display B
(Cause 1) Motor encoder section may be defective.
(Cause 2) Encoder cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Turn off the power and check for loose connections between the sections of the motor and
signal cable.
(2) Re-start.
(3) If the device can’t be reset even after the above check, contact our service personnel because
the signal cable may be broken or the motor defective.
(Cause 1) The sensor may be defective.
(Cause 2) The cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can't be re-started, contact our service personnel because a sensor or sensor
cable replacement might be required.
3. Trouble Shooting after Error Display
0005-002 2-8 Tg0248-PM-ER
01 01 03 XA-AXIS ORIGIN ORIGIN SENSOR (SLIDE) AND/OR LIMIT SENSOR (+)
MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can't be re-started, contact our service personnel.

(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 01 04 XA-AXIS ORIGIN ENCODER ORIGIN WAS DETECTED AT POINT OUT
OF ORIGIN (SLIDE).
Error Code Display A Display B
(Cause 1) Is the original position deviated?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Re-adjust the original position.
(2) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
01 01 05 XA-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS. ZEROING IS
REQUIRED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 01 10 XA-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 01 11 XA-AXIS ORIGIN LIMIT SENSOR (+)/(−) MIGHT BE DEFECTIVE.
01 01 06 XA-AXIS ORIGIN THE AXIS WAS NOT AT ORIGIN.
0005-002 2-9 Tg0248-PM-ER
3. Trouble Shooting after Error Display

01 02 01 XA-AXIS TIMING PREVIOUS TASK WAS NOT COMPLETED. UNABLE
TO CONTINUE.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 03 01 XA-AXIS DATA TARGET LOCATION VALUE IS OUT OF RANGE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 03 02 XA-AXIS DATA CORRECTION VALUE IS OUT OF FEEDER (B) OFF-
SET RANGE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0005-002 2-10 Tg0248-PM-ER
3. Trouble Shooting after Error Display
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 04 01 XA-AXIS LIMIT LIMIT ERROR (+) IS DETECTED.
;C(A)-BPH025 E / NR
01 04 02 XA-AXIS LIMIT LIMIT ERROR (−) IS DETECTED.
;C(A)-BPH026 E / NR