3OM-1064-001 - 第53页

01 05 14 XA-AXIS SERVOMOT OR DRIVER ABNORMAL DA T A SETTING W AS DETECTED. Error Code Display A Display B (Cause 1) This is the device’ s self-diagnostic message. (Reset Procedure in the case of Cause 1) Reset Procedure …

100%1 / 308
01 05 05 XA-AXIS SERVOMOTOR
DRIVER
ABNORMAL POWER LINE VOLTAGE WAS DE-
TECTED.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 05 06 XA-AXIS SERVOMOTOR
DRIVER
OVERSPEEDING OR ENCODER TROUBLE WAS
DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 05 08 XA-AXIS SERVOMOTOR
DRIVER
OVERLOAD WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 05 10 XA-AXIS SERVOMOTOR
DRIVER
MOTOR CONTROLLER STATUS: ALARM DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
3. Trouble Shooting after Error Display
0009-003 2-12 Tg0248-PM-ER
01 05 14 XA-AXIS SERVOMOTOR
DRIVER
ABNORMAL DATA SETTING WAS DETECTED.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
01 06 01 XA-AXIS INTERLOCK
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
3. Trouble Shooting after Error Display
0009-001 2-12-1 Tg0248-PM-ER
02 01 01 YA-AXIS ORIGIN ENCODER ORIGIN WAS NOT DETECTED.
02 01 02 YA-AXIS ORIGIN ORIGIN (SLIDE) WAS NOT DETECTED.
;C(A)-BPH021 E / R
02 01 03 YA-AXIS ORIGIN ORIGIN SENSOR (SLIDE) AND/OR LIMIT SENSOR (+)
MIGHT BE DEFECTIVE.
Error Code Display A Display B
(Cause 1) Motor encoder section may be defective.
(Cause 2) Encoder cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Turn off the power and check for loose connections between the sections of the motor and
signal cable.
(2) Re-start.
(3) If the device can’t be reset even after the above check, contact our service personnel because
the signal cable may be broken or the motor defective.
(Cause 1) The sensor may be defective.
(Cause 2) The cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [RESET] button to cancel the error indication.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel because a sensor or sensor
cable replacement might be required.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
3. Trouble Shooting after Error Display
0005-002 2-13 Tg0248-PM-ER