03 01 01 XB-AXIS ORIGIN 3. T rouble Shooting after Error Display 0005-002 2-18 Tg0248-PM-ER (Cause 1) Motor encoder section may be defective. (Cause 2) Encoder cable may be broken. (Reset Procedure in the case of Causes …

100%1 / 308
02 05 05 YA-AXIS SERVOMOTOR
DRIVER
ABNORMAL POWER LINE VOLTAGE WAS
DETECTED.
Error Code Display A Display B
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
02 05 06 YA-AXIS SERVOMOTOR
DRIVER
OVERSPEEDING OR ENCODER TROUBLE WAS
DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
02 05 08 YA-AXIS SERVOMOTOR
DRIVER
OVERLOAD WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
02 05 14 YA-AXIS SERVOMOTOR
DRIVER
ABNORMAL DATA SETTING WAS DETECTED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
02 06 01 YA-AXIS INTERLOCK
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
0005-002 2-17 Tg0248-PM-ER
3. Trouble Shooting after Error Display
03 01 01 XB-AXIS ORIGIN
3. Trouble Shooting after Error Display
0005-002 2-18 Tg0248-PM-ER
(Cause 1) Motor encoder section may be defective.
(Cause 2) Encoder cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Turn off the power and check for loose connections between the sections of the motor and
signal cable.
(2) Re-start.
(3) If the device can’t be reset even after the above check, contact our service personnel because
the signal cable may be broken or the motor defective.
03 01 02 XB-AXIS ORIGIN ORIGIN (SLIDE) WAS NOT DETECTED.
;C(B)-BPH024 E/R
(Cause 1) The sensor may be defective.
(Cause 2) The cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel because a sensor or sensor
cable replacement might be required.
03 01 03 XB-AXIS ORIGIN ORIGIN SENSOR (SLIDE) AND/OR LIMIT SENSOR (-)
MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
ENCODER ORIGIN WAS NOT DETECTED.
3. Trouble Shooting after Error Display
0005-002 2-19 Tg0248-PM-ER
03 01 05 XB-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
ZEROING IS REQUIRED.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
03 01 06 XB-AXIS ORIGIN THE AXIS WAS NOT AT ORIGIN.
03 01 10 XB-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
(Cause 1) Is the original position deviated?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Re-adjust the original position.
(2) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
03 01 04 XB-AXIS ORIGIN ENCODER ORIGIN WAS DETECTED AT POINT OUT
OF ORIGIN (SLIDE).
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.