05 01 05 LA1-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS. ZEROING IS REQUIRED. (Cause 1) This is the device’ s self-diagnostic message. (Reset Procedure in the case of Cause 1) Reset Procedure (1) Press the [CLEAR ALARM]…

05 01 04 LA1-AXIS ORIGIN ENCODER ORIGIN WAS DETECTED AT POINT OUT
OF ORIGIN (SLIDE).
(Cause 1) Is the original position deviated?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-29 Tg0248-PM-ER
3. Trouble Shooting after Error Display
05 01 03 LA1-AXIS ORIGIN ORIGIN (SLIDE) AND / OR LIMIT SENSOR (−) MIGHT
BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 01 02 LA1-AXIS ORIGIN ORIGIN (SLIDE) WAS NOT DETECTED.
;C(A1)-BPH121 E / R
(Cause 1) The sensor may be defective.
(Cause 2) The cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel because a sensor or sensor
cable replacement might be required.

05 01 05 LA1-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
ZEROING IS REQUIRED.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 01 06 LA1-AXIS ORIGIN THE AXIS WAS NOT AT ORIGIN.
05 01 10 LA1-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
3. Trouble Shooting after Error Display
Error Code Display A Display B
0005-002 2-30 Tg0248-PM-ER
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.

Error Code Display A Display B
0005-002 2-31 Tg0248-PM-ER
3. Trouble Shooting after Error Display
05 03 01 LA1-AXIS DATA TARGET LOCATION VALUE IS OUT OF RANGE.
(Cause 1) This is the device's self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 02 01 LA1-AXIS TIMING PREVIOUS TASK WAS NOT COMPLETED.
UNABLE TO CONTINUE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 01 11 LA1-AXIS ORIGIN LIMIT SENSOR (+)/(−) MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
05 04 01 LA1-AXIS LIMIT LIMIT ERROR (+) IS DETECTED.;C(A1)-BPH122 E/NR
05 04 02 LA1-AXIS LIMIT LIMIT ERROR (−) IS DETECTED.;C(A1)-BPH123 E/NR
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.