prober-english - 第3页

3 4 inch 6 inch Model HMP-400 / HMP-600 ・ Model HM P-400 is for 4" wafers. ・ Model HM P-600 is for 6" wafers. Bestselling  Compact  Manual  Prober This  is  a  compact  manual  prober  for  R&D  …

100%1 / 32
Wafersize2”to12
ManualandSemiautomatic
Ultralow currentmeasurementinfAlevel
Low capacitancemeasurementinfF level
Highfrequency measurementupto67GHz
Thermaltestfrom‐65Cto+400C(Atmospheric)
Thermaltestfrom 4kto+500C(Vacuum)
1/fnoise,RTNmeasurement
PulseIVtest,Ultra
highspeedIVtest
Highcurrentmeasurement(200Apulse)
Highvoltagemeasurement(10kV)
Electrostaticdischarge(ESD)evaluation
Failureanalysis
Magneticstimulation measurement
Optoelectronics (VCSEL,PDetc.)measurement
Waferlevelreliabilitytest (EM/TDDB/HCI/NBTI/BT)
From
From
UltraLow
UltraLow
SignaltoHighPower
SignaltoHighPower
test
test
,
,
FromDC
FromDC
I
I
V
V
C
C
V
V
m
m
easurement
easurement
toRF
toRF
m
m
easurement
easurement
OurProbingSolutions
WeofferyouanalysisprobesystemsforsemiconductorandFPD (Flatpaneldisplay).
Wecanprovidevariousprobesystemsfromaffordablecompactmanual probersforR&Dtohighend
300mmsemiautomatic probesystemfor‐65Cto+300Cthermaltest.
Wecancustomizethemostsuitableprobing solutionthatmatchestoyourmeasurement
application.
Ourprobesystemscorrespondtowidevarietyofapplicationfrom ultra lowsignaltesttohighpower
devicetest,fromDCparametric measurementtoRFmeasurement,waferlevelreliabilitytest,
magnetic fieldimpressionmeasurement,andopticaldevicemeasurement.
WesupportyourdevelopmentofR&Dandtechnicalimprovement.
HiSOL,Inc.isacertifiedsolutionpartnercompany
ofKEYSIGHTTechnologies
ManualProber
SemiAutomaticProber
ProbeSystemforFPD
Vacuumprobesystem
Specialty Probesystem
Accessories
Applications
2
3
4inch 6inch
Model HMP-400 / HMP-600
Model HMP-400 is for 4" wafers.
Model HMP-600 is for 6" wafers.
BestsellingCompactManualProber
ThisisacompactmanualproberforR&Dthatsupportswafermeasurementsrangingfromsmallchip upto4” or6” wafers.
Proberiscapableofmeasuringultra low curren tsonthefAlevelorlowcapacitanceonthepFlevelbyselectingappropriate
options.
Hightemperaturetestscanbealsomadebyincorporatingahotchuck
thatsupportsatemperaturerangefrom
roomtemperature to+300°C.
UltralowsignalIVmeasurements(fAlevel)
VariousCVmeasurements(quasistaticCV,HFCV)
4terminalresistancemeasurements
Temperaturecharacteristicstestsinrangefromroomtemperature to
+200°Cor+300°C
Mountsinglovebox
Probecardsupport
RFmeasurements(upto67 GHz)
UltrahighspeedIVmeasurements
Highpowerdevicemeasurements
(100Apulse,±3kVtriaxial,±10kVcoaxial)
Lightreceiving/emittingcharacteristicsevaluationapplicationsfor
optoelectronics (suchasLED,
LD,VCSEL,andPD)
Extended applications
Applications
MANUAL PROBER
Wafer Size
XYcoarsetravel
XYfinetravel
θ travel
PlatenZaxisaction
UnitdimensionW×D×H*
Weight*
PlatenZaxisadjustment
HMP400 HMP600
upto φ100mm upto φ150mm
X105mmY150mm X155mmY200mm
350×390×450mm
390×450×450mm
28kg 36kg
XY13mm / Micrometerhead
coarse±30°,fine±2.5°
0‐ 20mmfree
015mm
*Itemswithasteriskvarydependingonsystemconfiguration.
ManualProber
4
8inch 12inch
Model HMP-800 / HMP-1200
Thisisastandardmanualproberthatsupports8”or12”wafers.
Model HMP-800 is for 8" wafers.
Model HMP-1200 is for 12" wafers.
Thisprobersupportsreliableonwafermeasurementswithasimpleyethighaccuracymechanismthatiseasytooperate.
Thisstandardmanualprobermodelisscalabletosupportawiderangeofapplicationssuchashotchucksystems
(fromroomtemperatureto+200°Cor+300°C),submicronresolutionstages,and
lasercutters.
Applications
Temperaturecharacteristicstestsinrangefrom+20°Cto+300°C
UltralowsignalIVmeasurements(fAlevel)
VariousCVmeasurements(quasistaticCV,HFCV,andRFCV)
RFmeasurements(upto67GHz)
UltrahighspeedIVmeasurements
Extended applications
Probecardsupport(cansupportMultisiteWLR)
Builtinlasercutter(Pointmarking,Exfoliationofprotectionlayer,
Metallayercutting)
Probingwithsubmicronaccuracyachievedbyabuiltin
metallograph,activevibrationisolator,andultrahighaccuracy stage
Lightreceiving/emittingcharacteristicsevaluationapplications
foroptoelectronics (suchasLED,LD,VCSEL,andPD)
Common
gatepad contactsofflatpaneldisplaydevices
Highpowerdevicemeasurements
(200Apulse,±3kVtriaxial,±10kVcoaxial)
Waferlevelreliabilitytests(suchasEM,TDDB,HCI,NBTI,andBT)
MANUAL PROBER
WaferSize
XYcoarsetravel
XYfinetravel
θ travel
PlatenZaxisaction
UnitdimensionW×D×H*
Weight*
PlatenZaxisadjustment
HMP800 HMP1200
~φ200mm ~φ300mm
X205mmY300mm X305mmY400mm
550×650×450mm
690×780×450mm
60kg 80kg
XY13mm/Micrometerhead
coarse±30°,fine±2.5°
0/0.3/10mm
013mm
*Itemswithasteriskvarydependingonsystemconfiguration.
ManualProber