YSi-X_Ope_E - 第45页
1-4 1 Part names and functions n Behind panel (lower front and lower rear) tooltip Power connection terminals Main breaker Main breaker cable YSi-X main unit ■ Behind lower center of front panel Controller UPS (uninterru…

1-3
1
Part names and functions
n
Behind panel (lower left front)
LAN connector
Pressure regulator for shutter
Main pressure regulator
USB port
Air supply/shutoff switch
Source air connector
YSi-X main unit
Behind lower left front panel
23103-M6-00
Air supply/shutoff switch
Turning this switch to the right shuts off air supply and exhausts air that remains in the air path of the main unit.
Main pressure regulator
Adjusts the air pressure supplied to this machine. Turn the knob to adjust the air pressure so that the black needle on the
pressure gauge reads 0.4MPa.
Pressure regulator for shutter
Adjusts the air pressure to drive the shutter. Turn the knob to adjust the air pressure to 0.25MPa.
Source air connector
Prepare an air hose with an inner diameter of at least 8mm having a 30SH socket (Nitto Koki, or equivalent), and connect
it to this connector. Use dry, clean air passed through an air filter.
USB port
Use this USB port when making a backup of data.
LAN connector
This can be used for Ethernet connection.

1-4
1
Part names and functions
n
Behind panel (lower front and lower rear)
tooltip
Power
connection
terminals
Main breaker
Main breaker cable
YSi-X main unit
■ Behind lower center of front panel
Controller
UPS
(uninterruptible power supply)
■ Behind lower right of front panel
23104-M6-00
YSi-X main unit
Type HD/Type HB
■ Behind lower center of front panel
Controller UPS (uninterruptible power supply)
■ Behind lower center of rear panel
23109-M6-00
Power terminal block
Connects a 3-phase AC power cable to this terminal block. (For more details, see Appendix 1, "Power connection terminals".)
UPS (uninterruptible power supply)
The UPS retains (backs up) the power even if abnormal conditions such as power failure or voltage fluctuations occur.
(For more details, see Appendix 3, "UPS (uninterruptible power supply)".
n
Machine-to-machine connection connectors
Connector labeled "NEXT INTERFACE" connects to the downstream machine, and the connector labeled "PREVIOUS
INTERFACE" connects to the upstream machine. (For more details, see Appendix 2, "Connection between machines".
Machine-to-machine connection connectors
Behind rear panel
NEXT INTERFACE connector
(For connection to downstream machine)
PREVIOUS INTERFACE connector
(For connection to upstream machine)
23105-M6-10

1-5
1
Part names and functions
2.
Conveyor unit
2. Board stopper1. Board clamp unit
Conveyor unit
YSi-X conveyor unit
23106-M6-10
1. Board clamp unit
This unit clamps a board in place for inspection.
There are two clamping methods: one is the board clamp that secures the board from the top and bottom and the other is
the side clamp that secures the board by pushing laterally on the board edge (W-axis direction).
2. Board stopper
When a board is carried in on the conveyor, the board stopper stops it in the clamping position.
Board sensor
Board sensors are arranged at the conveyor entrance and exit, and also at the board clamp position.