User manual SIPLACE TX V2 3 Technical data and assemblies From software version 711.1 04/2018 3.5 Placement head 113 3.5.4 SIPLACE MultiS t ar CPP 3 3 Fig. 3.5 - 4 SIPLACE MultiSt ar - front view , function groups part 1…

3 Technical data and assemblies User manual SIPLACE TX V2
3.5 Placement head From software version 711.1 04/2018
112
3.5.3.5 Frequency converter (optional)
For details, refer to the assembly instructions for this option.
3
If the frequency converter is present, you must attach the warning label "high leakage current" at
location 1.
3
Fig. 3.5 - 3 Warning label "High leakage current", item no. 03155631-xx
CAUTION
The frequency converter may only be take into operation by qualified personnel!
The electrical connection and taking into operation of the frequency converter may only
be conducted by specifically qualified personnel.

User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.5 Placement head
113
3.5.4 SIPLACE MultiStar CPP
3
3
Fig. 3.5 - 4 SIPLACE MultiStar - front view, function groups part 1
(1) Handle
(2) Star with 12 segments
(3) Segment with integrated DP drive
CAUTION
Always take hold of the handle to push the placement head
The placement head may only be moved by pushing manually against the handle provid-
ed.
(2)
(3)
(1)

3 Technical data and assemblies User manual SIPLACE TX V2
3.5 Placement head From software version 711.1 04/2018
114
3
Fig. 3.5 - 5 SIPLACE MultiStar - front view, function groups part 2
(1) C&P component camera, type 30, 27 x 27, digital
(2) Torque motor for star drive
(3) Z drive (linear motor)
(4) Return cylinder
(5) Pressure control valve
(1)