00198442-01_UM_TX-V2_EN - 第177页

User manual SIPLACE TX V2 4 Setting up and commissioning From software version 711.1 04/2018 4.5 Setting up the placement machine 177 4.5.2.2 Removing the shipping bra ce on the Y axis 4 Fig. 4.5 - 2 Shipping brace on th…

100%1 / 304
4 Setting up and commissioning User manual SIPLACE TX V2
4.5 Setting up the placement machine From software version 711.1 04/2018
176
4.5.2 Removing the shipping braces from the gantries
The gantries are secured with a shipping brace in both the X and Y directions. After transportation
of the placement machine, remove the shipping braces.
4.5.2.1 Removing the shipping brace on the X axis
4
Fig. 4.5 - 1 Shipping brace on the X axis
4
Loosen the screw (1) on the shipping brace (2) so that the shipping brace can be easily taken
off the linear guide.
4
CAUTION
Do not damage the scale!
The scale is located under the shipping brace (2).
Make sure that the scale (3) under the shipping brace is not damaged.
(1)
(3)
(2)
(4)
User manual SIPLACE TX V2 4 Setting up and commissioning
From software version 711.1 04/2018 4.5 Setting up the placement machine
177
4.5.2.2 Removing the shipping brace on the Y axis
4
Fig. 4.5 - 2 Shipping brace on the Y axis
Loosen the counternut (2) holding the shipping brace (3) on the buffer plate (1) of the end
position stop.
Unscrew the counternut (2) 20 to 30 mm away from the buffer plate (1).
Use a size 13 fork wrench to loosen the shipping brace (3) from the gantry end (4) and un-
screw the shipping brace (3). Make sure you use the correct direction of rotation so that the
thread is not damaged.
Push the gantry to one side.
Unscrew the shipping brace completely from the buffer plate.
Keep the shipping brace safely for use later on. If the SIPLACE machine needs to be trans-
ported, always fit the shipping braces again.
(1)
(3)
(2)
(4)
4 Setting up and commissioning User manual SIPLACE TX V2
4.5 Setting up the placement machine From software version 711.1 04/2018
178
4.5.3 Fitting the shipping braces on the gantry axes
Before you transport the placement machine, always secure the X and Y axis of the gantry axes
with a shipping brace each. Fit these shipping braces.
4.5.3.1 Fitting the shipping brace on the X axis again
The shipping brace on the X axis fastens the head plate with the placement head on the gantry.
4
See also fig. 4.5 - 1, page 176).
Loosen the screw on the shipping brace so that the shipping brace can be easily fitted onto
the linear guide.
Push the placement head and the shipping brace up to the gantry base/input end.
Fit the shipping brace so that the placement head is fastened to the gantry base. The ridges
(item 4 in fig. 4.5 - 1
, page 176) on the shipping brace point towards the head.
Loosely tighten the screw on the shipping brace.
Press the placement head firmly towards the gantry base/input end again so that the place-
ment head has no play.
Tighten the screw on the shipping brace firmly.
CAUTION
Do not damage the scale!
The scale is located under the shipping brace
Make sure that the scale (3) under the shipping brace is not damaged.