00198442-01_UM_TX-V2_EN - 第270页

6 Station extensions Use r manual SIPLACE TX V2 6.1 Nozzle changer From software version 711.1 04/2018 274 6.1.4.3 Configuration example with SI PLACE T winSt ar Location 1 can accommodate a nozzle ch anger with eight ma…

100%1 / 304
User manual SIPLACE TX V2 6 Station extensions
From software version 711.1 04/2018 6.1 Nozzle changer
273
6.1.4.2 Technical data
6
Nozzle changer for the SIPLACE TwinStar
Number of magazines
Location 1 6 Max. 8 magazines for max. 16 nozzle garages
Number of nozzle holders may be freely configured
Standard configuration 3 magazines with two nozzle garages each
1 magazine with one nozzle garage
Nozzle types 5xx (standard)
20xx / 28xx (with nozzle adapter 20xx/28xx on 5xx)
Special nozzles, gripper
6 Station extensions User manual SIPLACE TX V2
6.1 Nozzle changer From software version 711.1 04/2018
274
6.1.4.3 Configuration example with SIPLACE TwinStar
Location 1 can accommodate a nozzle changer with eight magazines for the TwinStar (item 1 in
fig. 6.1 - 12
, page 274).
6
Fig. 6.1 - 12 Position of nozzle changer for the TwinStar - configuration example of SIPLACE TX2
6
NC CPP
Nozzle changer for the CPP with 4 magazines
COT 40 In
Component trolley in the innermost position
COT 40 Out
Component trolley in the outermost position
IC
Stationary camera
NC TH
Nozzle changer for the TwinStar
User manual SIPLACE TX V2 6 Station extensions
From software version 711.1 04/2018 6.1 Nozzle changer
275
6.1.4.4 Assembly
The nozzle changer is fixed to the COT insert.
6
Fig. 6.1 - 13 Assembly position
(1) Marking hole
(2) Operator side
(3) Arrow pointing toward the PCB conveyor
6
Align the nozzle changer so that the marking hole (item 1) is on the left, as viewed by the op-
erator.
(1)
(2)
(3)