00198442-01_UM_TX-V2_EN - 第95页

User manual SIPLACE TX V2 3 Technical data and assemblies From software version 711.1 04/2018 3.1 Performance data 95 3 T echnical dat a and assemblies 3.1 Performance dat a 3.1.1 Definition of placement performance The …

100%1 / 304
2 Operational safety User manual SIPLACE TX V2
2.9 ESD guidelines From software version 711.1 04/2018
94
User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.1 Performance data
95
3 Technical data and assemblies
3.1 Performance data
3.1.1 Definition of placement performance
The placement performance is influenced by the different head combinations and head positions,
plus the conveyor configurations. Individual options and customized applications also influence
the placement performance. On request, SIPLACE can calculate the actual performance of your
product on your placement machine configuration.
IPC value [components/h]
Performed with 0402 components in accordance with the layout of the IPC 9850 standard from
the Association of Connecting Electronics Industries.
SIPLACE benchmark value [components/h]
The SIPLACE benchmark value fulfills the requirements in the SIPLACE scope of delivery and
performance.
Theoretical maximum output value [components/h]
The theoretical maximum output value is calculated from the most favorable conditions for each
placement machine type and setting, and corresponds to the theoretical conditions normally used
in the industry.
3 Technical data and assemblies User manual SIPLACE TX V2
3.1 Performance data From software version 711.1 04/2018
96
3.1.2 Placement capacity SIPLACE TX
3
Placement head types SIPLACE SpeedStar (C&P20 P2)
SIPLACE MultiStar (CPP)
SIPLACE TwinStar (TH)
Placement performance
For a definition of placement performance values, see section 3.1.1 on page 95.
SIPLACE TX2i placement
machine
Placement area IPC value Benchmark value
C&P20 P2 / C&P20 P2 79,000 96,000
CPP_L/CPP_L 46,000 51,000
SIPLACE TX2 placement
machine
Placement area IPC value Benchmark value
C&P20 P2 / C&P20 P2 72,300 85,500
C&P20 P2 / CPP_L 57,800 66,600
CPP_L/CPP_L 43,300 47,700
CPP_H / CPP_H 40,800 44,700
TH / CPP_H 25,500 29,000
SIPLACE TX1 placement
machine
Placement area IPC value Benchmark value
C&P20 P2 36,100 44,000
CPP_H 20,500 22,500
TH 5,050 5,500
CPP_H = Multistar CPP in high assembly position
CPP_L = Multistar CPP in low assembly position