00196775-0102_OM_DockingStation_SX_EN - 第22页
3 Product Description Docking Station for SIPLACE SX Changeover Tables 3.2 Technical Data Operating Manual 18 3.2.1 Dimensions with docked changeover table 654 801.5 178 1 2 Fig. 3 - 3 Docking station SIPLACE SX with doc…

17
Docking Station for SIPLACE SX Changeover Tables 3 Product Description
Operating Manual 3.2 Technical Data
3.2 Technical Data
1
2
3
801.5
859
889
909
Height to centring pin
(1) Compressed-air connection
(2) CAN bus port
(3) Power supply socket
1038
Fig. 3 - 2 Docking station SIPLACE SX – dimensions in millimetres, connections
Length x width 801.5 mm x 1038 mm
Height (to centring pin) 859 mm at 900 mm PCB conveyor height
889 mm at 930 mm PCB conveyor height
909 mm at 950 mm PCB conveyor height
Weight 105 kg
Compressed-air connection p
min.
0.5 MPa (5.0 bar)
p
max.
1.0 MPa (10.0 bar)
Compressed-air connection Coupling connector KS 2-M5-A
Flow 5 Nl/min
a
a. Under atmospheric standard conditions at 20°C and 1013 hPa
Supply voltage 88 - 264 V AC
No. of wires / phases 3 / 1
Frequency max. 63 Hz
Rated current max. 2 A
Power 0.23 kW
Protection 2 x 8 A

3 Product Description Docking Station for SIPLACE SX Changeover Tables
3.2 Technical Data Operating Manual
18
3.2.1 Dimensions with docked changeover table
654 801.5
178
1
2
Fig. 3 - 3 Docking station SIPLACE SX with docked changeover table – dimensions in millimetres
(1) Changeover table
(2) Docking station

19
Docking Station for SIPLACE SX Changeover Tables 3 Product Description
Operating Manual 3.3 Transport Lock
3.3 Transport Lock
After unpacking and before using the docking station for the first time, be sure to remove the
transport locks.
1
2
3
Fig. 3 - 4 Transport locks
(1) 2x shaft transport lock on the lifting axis
(2) 4x side wall transport locks
(3) Storage place for transport locks (1)
To loosen the transport lock (1), you need to remove the rear cover. Loosen the transport lock (1)
and fix it loosely to the storage place (3). Replace the cover.
To remove the transport lock (2), cut the four red cable ties with a suitable tool.