N7201A652E - 第273页
NPM- TT2 EJM1EE-MB -04O-03 The offset data of lamp value is initialized. 1 Checking and editing the recognition condition 4-1-9 -2 C B Item name Set data Mount condition of each item. D A CompName (→P.4-1-8 -1 ) Edit the…

NPM-TT2 EJM1EE-MB-04O-03
Data
editing
Describes how to check and edit the mount condition data for the components registered in each feeder
address.
C
B
Item name
Set data
Mount condition of each item.
Checking and editing pickup, mount, nozzle condition
Placement condition
data edit
D
Switching condition setting
●
●
●
●
Please see the Operating manual of NPM-DGS for setting of each item.
NOTICE
A
CompName
(→P.4-1-8-1)
Edit the data of the desired
field on the screen
●Touching the screen opens the input
window.
1
Operating procedure
4-1-9
D B C
A
●
This is displayed only if ‘Vertical line
camera measurement’ in the unit
setting is set to ‘ON’. (→P.5-1-1)
4-1-9-1

NPM-TT2 EJM1EE-MB-04O-03
The offset data of lamp value is
initialized.
1
Checking and editing the recognition condition
4-1-9-2
C
B
Item name
Set data
Mount condition of each item.
D
A
CompName
(→P.4-1-8-1)
Edit the data of the desired
field on the screen
●Touching the screen opens the input
window.
2
Setting
change
1 B CD
A
Recog. Speed:
・(Auto / Fast / Mid / Slow)
Recog error stop:
・(1 / 3)
Camera kind:
・(2D / 3D)
Lighting mode:
・(Shadow / Reflect / BGA)
Shadow lamp offset:
・Shadow lamp offset value for component
recognition
Reflect lamp offset:
・Reflect lamp offset value for component recognition
BGA lamp offset:
・BGA lamp offset for component recognition
polarity:
・The presence / absence of component polarity
Chk adhesion around the parts:
・Picking up 2 components results in a recognition
error. Prevents an extra component from falling on a
PCB.

NPM-TT2 EJM1EE-MB-04O-03
Data
editing
Describes how to check and edit tray information.
B
CD E F G
Tray data edit
(tray feeder)
AH
A
CompName
(→P.4-1-8-1)
B
Tray
Tray name.
C
Basic information
(→P.4-1-10-2)
Choose a moving speed of pallet axis.
D
Pallet axis speed
E
Lifter axis speed
Choose a moving speed of lifter-axis.
●Choose the same set data as .
D
F
Tray thickness
G
Pickup height
Tray
Electric
component
Pickup
height
Enter the pickup height.
Edit the data of the desired
field on the screen
●Touching the screen opens the input
window.
1
Operating procedure
4-1-10
4-1-10-1