NPM- TT2 EJM1E E-MB-05O-05 5-1-2 -12 System administration Setting information 1 1 ■ Feeder (6/6) Type Item Description Initial value Setting range Determine Whole Feed Length[mm] When “Action when joint detecte d” is “0…

NPM-TT2 EJM1EE-MB-05O-05
Unit
setting
Action parameter
setting 6
5-1-2-11
Setting information 10
Operating procedure
5-1-2
■Feeder (5/5)
Type Item Description Initial
value
Setting
range
Determine
Auto Tape Moving
Remain [%]
Even if parts are fed as many times as the
set value after the remaining number of the
parts being used reaching 0, information on
all parts in the splicing unit will be reflected
in the unit where parts are used if any splice
joint is not detected.
●Enabled when feeder verification or
remaining warning is set to ON.
00 to 15
The remains when the
joint not pass is
selected[%]
When the machine stops after the number of
remaining parts reaches “1”, selecting “the
join not pass” sets the “default value x the
setting value” as the remaining number of
parts.
0 0.0 to 100.0
Unfixed cnt. before
Splicing [piece]
Ignores as many errors as the number of the
parts set at the trailing edge of the reel on
the machine side after completion of splicing.
Because the improper taping of splicing tape
is likely to cause pickup errors, this is used to
ignore such errors as an unstable zone.
00 to 3
Feed length
(8mm) [mm]
When production starts, the number of chips
obtained from specified length / pitch is
compared with the number of chips currently
set on workpiece exhaust, and the larger one
is applied for the number of workpiece
exhaust chips.
●Applicable feeder: 8mm or less (Paper,
embossed).
0 0.0 to 120.0
Pickup position gap
retry count
When a pickup position gap has occurred, a
retry can be attempted in combination with
pickup position teaching as many times as
specified by this setting value.
00to5
In pickup position
teach Tape feed limit
judge value[Piece]
When the tape feed in pickup position
teaching has exceeded the limit length
(Judge value x Feed pitch), tape feed will be
limited.
00 to20
Splicing Position
Unfixed Length[mm]
When this value is other than 0 and “joint
detection” in the mount condition data is “1.
Excluded from errors”, unfixed count
processing is carried out for the length set
here. Fractions are rounded up. (When
excluded from errors, the “Whole Feed
Count” is handled as “Splicing Position
Unfixed Count”.
0.0
0.0 to
100.0

NPM-TT2 EJM1EE-MB-05O-05
5-1-2-12
System
administration
Setting information 11
■Feeder (6/6)
Type Item Description Initial
value
Setting
range
Determine
Whole Feed
Length[mm]
When “Action when joint detected” is “0:
Whole Feed (default)”, whole feed is
performed for the length set here. Fractions
are rounded up. “Whole Feed Count” in the
mount condition data prevails over this
setting.
0.0 0.0 to 100.0
Pickup again count
during pickup error
Set the number of times pickup is
reattempted for a pickup error.
11 to3
Unfixed length before
splicing[mm]
Pickup/recognition errors are not counted for
the length set here from the splicing position
on the old reel side.
00to40
Unfixed Length After
Whole Feed[mm]
Pickup/recognition errors are not counted for
the length set here after a whole feed.
00 to40
Feeder defective rate
measure count[cnt]
This is used when Feeder defective rate
warning (specified count) is ON.
Feeder defective rate is calculated when the
measurement count reaches the value set
here.
100
100 to
10000
Terminal detect action
execute judge[%]
This is used to determine whether or not to
perform end detection for the parts fed by
auto loading feeder when “Pickup error stop”
is set at “1” in the mount condition data.
When a pickup error has occurred, end
detection is performed if the following
condition is met: Number of remaining parts
< Initial part quantity x End detection judge
remain[%]. If the end of tape is not detected,
the machine will stop due to a pickup error.
(End detection is not performed when this is
set at 0.)
0.50
0.00 to
10.00
■Transfer (1/2)
Type Item Description Initial
value
Setting
range
Mechanic
Transcription unit film
formation speed
[mm/s]
The maximum speed for forming film. 75 0 to 500
Transcription unit
taking out speed
[mm/s]
The maximum speed for scraping and
retracting.
150 0 to 500

NPM-TT2 EJM1EE-MB-05O-05
Unit
setting
Action parameter
setting 7
5-1-2-13
Setting information 12
Operating procedure
5-1-2
■Line camera
Type Item Description Initial
value
Setting
range
Determine
Recog. OK rate [%]
This is a criterion used to judge recognition
results good or bad.
If “ANS” of recognition results falls short of it,
a recognition error occurs.
85 0 to 100
Bad mark judge rate
[%]
This is the threshold for bad mark
recognition block matching.
The block is judged to be OK if the result of
matching is equal to or greater than the
value set here.
85 0 to 100
Type Item Description Initial
value
Setting
range
Mechanic
Tray pickup place gap
[mm]
This gap is added in pickup from trays. 0.5 -2.0 to 2.0
■Tray
■ Transfer (2/2)
Type Item Description Initial
value
Setting
range
Timer
Time Keep thick film
time [s]
Coating thickness formation holding time
for the transcription unit.
30 0 to 600
Stamp material
Spill Detect Invalid
Time (F) [s]
After transcription materials at the front side
are automatically supplied, spill detection is
disabled during the set time period.
●It assumes the time between the start of
material dripping off and until dripping off
stops.
0.5 0.0 to 5.0
Stamp material
SpillDetect Invalid
Time (R) [s]
After transcription materials at the rear side
are automatically supplied, spill detection is
disabled during the set time period.
●It assumes the time between the start of
material dripping off and until dripping off
stops.
0.5 0 .0 to 5.0