NPM- TT2 EJM1E E-MB-05O-05 Machine parame- ter F eeder pic kup position/ tr anscription position of fset c hec k 5-3-12 Operating procedure 5-3-12 Feeder pickup position A B T ranscription position offset A B A B Cart po…

NPM-TT2 EJM1EE-MB-05O-05
5-3-11
Machine
parame-
ter
Tray origin offset/
pickup position check
Checking pickup position offset
A
A
Checking origin offset value
A
B
A
B
You can check the tray feeder for the pickup position offset of the tray feeder and the origin offset values of
TP-/TL-axes.
Operating procedure
5-3-11
●TP [mm]
Origin offset of TP-axis of the tray
feeder.
●TL [mm]
Origin offset of TL-axis of the tray
feeder.
Origin offset
Position offset X[mm]Y[mm]
Position offsets of marks A and B in X-
/Y-directions.
Position offset Z[mm]
Position offsets of mark C, D and E in Z-
direction.
System
administration

NPM-TT2 EJM1EE-MB-05O-05
Machine
parame-
ter
Feeder pickup position/
transcription position offset
check
5-3-12
Operating procedure
5-3-12
Feeder pickup position
A
B
Transcription position offset
A
B
A
B
Cart position offset
X[mm]/Y[mm]/Z[mm]
Position offset of the right/left carts.
Pickup position offset
X[mm]/Y[mm]/Z[mm]
Offset of feeder pickup position.
(X-/Y-/Z-coordinates)
Squeegee-axis offset
Trans pos offset Z[mm]
●Origin offset [pulse]
Origin offset of squeegee-axis.
●A: Gap 0.05mm[pulse]
Offset of the point A on squeegee-axis
(0.05mm position).
●B: Gap 0.50mm[pulse]
Offset of the point B on squeegee-axis
(0.50mm position).
Offset of transcription position in Z-axis
direction.
A B A
CD
C
D
Displays all values measured during
calibration. For the value shown as “-”,
it is measurement non-target data.
Displays the value measured when
pickup action is performed after feeder
cart is re-attached. Displays only the
value of a cart.

NPM-TT2 EJM1EE-MB-05O-05
5-3-13-1
System
administration
Machine
parame-
ter
Operating procedure
5-3-13
B
A
C
You can check the sensor offset value (calibration result) of the height sensor.
●Bank A, Bank B・・・Measurement range (resolution) of the height sensor can be changed.
On bank A and B, values measured in each range are used.
●For the dispensing head, only bank A is used.
A
B
X[mm]Y[mm]
Offset values of the height sensor
installation position.
C
Z[mm]
Offset values of the height sensor and
the standard nozzle.
Tilt, Section
Correction coefficient values for
calculation of the height sensor.
Height sensor offset