N7201A652E - 第469页

NPM- TT2 EJM1E E-MB-05O-05 5-3-13 -1 System administration Machine parame- ter Operating procedure 5-3-13 B A C You can check the sensor offset value (calibrat ion result) of the height senso r. ● Bank A, Bank B ・・・ Meas…

100%1 / 512
NPM-TT2 EJM1EE-MB-05O-05
Machine
parame-
ter
Feeder pickup position/
transcription position offset
check
5-3-12
Operating procedure
5-3-12
Feeder pickup position
A
B
Transcription position offset
A
B
A
B
Cart position offset
X[mm]/Y[mm]/Z[mm]
Position offset of the right/left carts.
Pickup position offset
X[mm]/Y[mm]/Z[mm]
Offset of feeder pickup position.
(X-/Y-/Z-coordinates)
Squeegee-axis offset
Trans pos offset Z[mm]
Origin offset [pulse]
Origin offset of squeegee-axis.
A: Gap 0.05mm[pulse]
Offset of the point A on squeegee-axis
(0.05mm position).
B: Gap 0.50mm[pulse]
Offset of the point B on squeegee-axis
(0.50mm position).
Offset of transcription position in Z-axis
direction.
A B A
CD
C
D
Displays all values measured during
calibration. For the value shown as “”,
it is measurement non-target data.
Displays the value measured when
pickup action is performed after feeder
cart is re-attached. Displays only the
value of a cart.
NPM-TT2 EJM1EE-MB-05O-05
5-3-13-1
System
administration
Machine
parame-
ter
Operating procedure
5-3-13
B
A
C
You can check the sensor offset value (calibration result) of the height sensor.
Bank A, Bank B・・・Measurement range (resolution) of the height sensor can be changed.
On bank A and B, values measured in each range are used.
For the dispensing head, only bank A is used.
A
B
X[mm]Y[mm]
Offset values of the height sensor
installation position.
C
Z[mm]
Offset values of the height sensor and
the standard nozzle.
Tilt, Section
Correction coefficient values for
calculation of the height sensor.
Height sensor offset
check
NPM-TT2 EJM1EE-MB-05O-05
5-3-13-2