User Manual SIPLACE Linear Dipping Unit 2 X - 第26页
3 Function description and structure 3.2 Structure 26 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 3.2.5 Dipping plate 1. Dipping plate 2. Cavity The following dipping plates without RFID transponder are available…

3 Function description and structure
3.2 Structure
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 25
If the amount of flux reaches the Error level, the station software displays a corresponding status
message:
NOTICE
Station software filters the measured values
Because the station software filters the measured values, the machine is not stopped if the
threshold is only exceeded briefly
Additionally, the station software also displays the warning message 31865 Dip Module: medium
empty. In this case, the LDU will be locked and components to be dipped will not be dipped and
placed.
See chapter 4.1.6 "Setting the Flux Level Sensor parameters" [}49] for how to operate the Flux
Level Sensor.
NOTICE
The LDU can also be operated with a park plate that does not have a Flux Level Sensor.
NOTICE
The Flux Level Sensor must be calibrated after an exchange of the park plate or the flux
tank. Please refer to the LDU 2 X service manual.

3 Function description and structure
3.2 Structure
26 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020
3.2.5 Dipping plate
1. Dipping plate
2. Cavity
The following dipping plates without RFID transponder are available for the LDU 2 X:
Item number Depth of cavity [µm] Item number Depth of cavity [µm]
03059408-xx - 03072948-xx 200
03063053-xx 20 03072958-xx 210
03078159-xx 25 03068486-xx 220
03063054-xx 30 03064360-xx 230
03063055-xx 40 03069330-xx 240
03070690-xx 45 03074835-xx 250
03063056-xx 50 03074808-xx 260
03063057-xx 60 03074844-xx 270
03063058-xx 70 03065213-xx 280
03066566-xx 75 03074850-xx 290
03063059-xx 80 03072530-xx 300
03063060-xx 90 03074853-xx 310
03063061-xx 100 03069331-xx 320
03072107-xx 110 03074856-xx 330
03069323-xx 120 03074891-xx 340
03072883-xx 130 03074894-xx 350
03072903-xx 140 03063106-xx 360
03072913-xx 150 03074899-xx 370
03072916-xx 160 03074904-xx 380
03072919-xx 170 03074909-xx 390
03072923-xx 180 03069332-xx 400
03072925-xx 190

3 Function description and structure
3.2 Structure
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 27
The following dipping plates with RFID transponder are available for the LDU 2 X:
Item number Depth of cavity [µm] Item number Depth of cavity [µm]
03168214-xx 10 03168286-xx 190
03168210-xx 15 03168287-xx 200
03168206-xx 20 03168288-xx 210
03168202-xx 25 03168289-xx 220
03168198-xx 30 03168290-xx 230
03168196-xx 35 03168291-xx 240
03168191-xx 40 03168292-xx 250
03168194-xx 45 03168293-xx 260
03168185-xx 50 03168294-xx 270
03168181-xx 60 03168295-xx 280
03167724-xx 70 03168296-xx 290
03168275-xx 80 03168297-xx 300
03168276-xx 90 03168298-xx 310
03168277-xx 100 03168299-xx 320
03168278-xx 110 03168300-xx 330
03168279-xx 120 03168301-xx 340
03168280-xx 130 03168302-xx 350
03168281-xx 140 03168303-xx 360
03168282-xx 150 03168304-xx 370
03168283-xx 160 03168305-xx 380
03168284-xx 170 03168306-xx 390
03168285-xx 180 03168307-xx 400
Dipping plate with adjustable cavity depth (only for LDU 2 X with Auto Cavity
option)
The adjustable cavity of the Auto Cavity dipping plate consists of a movable cavity plate, which is
connected to the dipping plate body by a flexible seal.
Dipping plate top side:
1. Dipping plate
2. Cavity plate
3. Seal
On the bottom side of the dipping plate, the cavity plate is supported by two stop plates, which
define the lowest position of the cavity plate and also ensure mechanical stability during the dipping
process.