4 Operation
4.1 Settings in SIPLACE Pro
50 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020
4.1.8 Setting the cavity depth and the pressing force
To obtain a good coating of a component with flux, a suitable cavity depth for dipping must be as-
signed to that component.
In SIPLACE Pro, click on the tab of the component shape of the desired component(1).
Click on the Handling tab(2) in the Object Properties view.
In the Dipping area, enter the cavity depth in micrometers [µm] in the Cavity depth entry
field(3)
.
NOTICE
Ensure that your setup contains at least one combination of cavity depth and flux
that matches the dipping requirements for this component (see chapter 4.1.3
"As-
signing a dipping plate and a flux to the LDU" [
}
46]).
In the Dipping area, from the Force menu (4), select the desired mode for the pressing force:
Standard
Specific
Very low
If you select Specific, you can enter the desired pressing force in Newton [N] in the entry field
to the right.
4 Operation
4.1 Settings in SIPLACE Pro
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 51
4.1.9 Setting the creep distance
In SIPLACE Pro, click on the tab of the component shape of the desired component(1).
Click on the Handling tab(2) in the Object Properties view.
Enable the Use custom creep distance option(3) under Creeping(3) in the Dipping area.
Enter the desired length of the creep distance in the Creep Distance entry field.
In the Speed down end entry field, enter the desired speed down.
In the Speed up start entry field, enter the desired speed up.
For more information to creep distance, speed down and speed up, see chapter 3.3.7 "Creep dis-
tance" [}38].
4.1.10 Setting the waiting time
Depending on the component and the flux used, it can be advantageous to hold the component on
the PCB for a short waiting time during the placement process.
In SIPLACE Pro, click on the tab of the component shape of the desired component(1).
Click on the Handling tab(2) in the Object Properties view.
Enter the Waiting time in milliseconds [ms] in the Waiting Time entry field (3) in the Place-
ment area.
4 Operation
4.1 Settings in SIPLACE Pro
52 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020
4.1.11 Setting the cicatrization time of the flux
If longer standstill (inactive) times during the production run can be expected, you should set the ci-
catrization time of the flux used. The LDU will then perform an application run after this period has
expired.
In SIPLACE Pro, click on the tab of the relevant flux(1).
Click on the tab of the flux(2) in the Object Properties view.
Enter the cicatrization time of the flux used in seconds [s] in the Cicatrization time entry field
in the Dip Flux Parameters
area(3).
Enter the curing time of the flux used in seconds[s] in the Curing time entry field in the Dip
Flux Parameters area(3).
Curing time defines the maximum time that must not be exceeded between dipping and pla-
cing a component.
For more information on the cicatrization time of fluxes, see chapter 3.3.3 "Cicatrization time" [}36].
4.1.12 Setting the warm-up cycles and the squeegee speed
During the warm-up cycle, the LDU performs a set number of squeegee processes to prepare the
flux.
The squeegee speed is the speed with which the squeegee axis applies the flux in the cavity.
In SIPLACE Pro, click on the tab of the relevant flux(1).