4 Operation 4.8 Operating the control unit via user interface 66 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 ► Click on the Self-test button. The LDU performs a self-test. 4.8 Operating the control unit via user …

100%1 / 90
4 Operation
4.6 Testing new flux types
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 65
4.6 Testing new flux types
NOTICE
Target group: setup operator
The procedure described is a task that occurs irregularly and should only be carried out by
a trained operator with special knowledge (setup operator).
If you use a new flux, then proceed as follows during the test phase:
Calculate the relevant cavity for the product.
Place the corresponding dipping plate in the LDU.
Fill in the flux.
Set the application speed.
Increase or decrease the application speed in steps.
While doing this, observe the flux surface.
Reduce the application speed again, if waves, dips or irregularities are formed on the surface.
Select a long dwell time. This can be reduced later to achieve higher cycle times.
Select a slow start for the upwards movement of the placement head after dipping. This en-
sures that the component is not lost in the flux.
4.7 Performing a self-test
NOTICE
Target group: setup operator
The procedure described is a task that occurs irregularly and should only be carried out by
a trained operator with special knowledge (setup operator).
In the station software, select the Single
functions view(1) and then the Subsys-
tems area (2).
Select the Location (3) on which the LDU
is set up.
Select the Feeder area (1).
Select the LDU in the list of set up feeders
(2)
.
Click on the Details…button (3).
4 Operation
4.8 Operating the control unit via user interface
66 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020
Click on the Self-test button.
The LDU performs a self-test.
4.8 Operating the control unit via user interface
NOTICE
Target group: setup operator
The procedure described is a task that occurs irregularly and should only be carried out by
a trained operator with special knowledge (setup operator).
NOTICE
Operating the control unit via GUI can be done by any trained operator.
Logging off
Use the Up(1) or Down key(2) to select the operating mode P0.
Press the Select key(3).
The LDU will be logged off and unlocked from the placement machine.
Remove the LDU from the changeover table.
4 Operation
4.8 Operating the control unit via user interface
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 67
Starting a reference run
Use the Up(1) or Down key(2) to select the operating mode P1.
Press the Select key(3).
The LDU performs a reference run.
Refreshing the dipping medium
Select with the Up (1) or Down key (2) the operating mode P2.
Press the Select key (3).
The LDU performs a squeegee movement.
Adjusting the squeegee speed
NOTICE
Only for testing the user interface
Regardless of these settings, Serio always uses the SIPLACE Pro settings!
Use the Up (1) or Down key(2) to select the operating mode P2.
Press and hold the Up key(1), to switch to the Advanced production
activity level.
Use the Up (1) or Down key (2) to select the operating mode P3.
Press the Select key (3).
Press the Up (1) or Down key (2) to increase or decrease the value of
the squeegee speed.
The squeegee speed in mm / s is shown in the 7 segment display 3/4.
Press the Select key(3) to save the value.