User Manual SIPLACE Linear Dipping Unit 2 X - 第70页
4 Operation 4.10 Positioning the LDU and logging on 70 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 4.10 Positioning the LDU and logging on NOTICE Target group: standard operator The procedure described is a regul…

4 Operation
4.9 Handling
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 69
Calibrating the axes
NOTICE
Only use after repair of the LDU
Calibrating the axes is only recommended after the LDU has been repaired!
► Use the Up (1) or Down key (2) to select the operating mode P1.
► Press and hold theSelect(3) and Adjust(4) keys simultaneously to
switch to the Service
activity level.
► Use the Up(1) or Down key(2) to select the operating mode P7.
► Press and hold the Adjust key(4) until the digits 01 are shown in the 7
segment display 3/4.
► Press the Select key(3).
The LDU performs an axis calibration.
4.9 Handling
NOTICE
Target group: standard operator
The procedure described is a regular task that can be carried out by any trained operator.
Always carry the LDU2X with both hands holding it as upright and horizontal as possible.
► Take the handle(1) of the LDU 2 X with
one hand and support the housing with the
other hand(2)
.

4 Operation
4.10 Positioning the LDU and logging on
70 User Manual SIPLACE Linear Dipping Unit 2 X 05/2020
4.10 Positioning the LDU and logging on
NOTICE
Target group: standard operator
The procedure described is a regular task that can be carried out by any trained operator.
NOTICE
Positioning the LDU on the correct track
► Position the LDU on the track of the changeover table which you defined during setup
(see chapter 4.1.1
"Setting up the LDU" [}39]).
► Place the LDU 2 X horizontally in the track
of the changeover table.
.
► Push the LDU 2 X forward against the
fixed stop of the track.
The LDU 2 X will be automatically locked,
switched on and logged on at the machine.

4 Operation
4.11 Starting a reference run
User Manual SIPLACE Linear Dipping Unit 2 X 05/2020 71
4.11 Starting a reference run
NOTICE
Target group: standard operator
The procedure described is a regular task that can be carried out by any trained operator.
After logging on, it is mandatory to perform a reference run so that the LDU can be set up and
used. During the reference run the axes are initialized. In the process, the end positions of the axes
are determined and moved to a defined position.
Requirements:
●
The squeegee must be positioned over the park plate at the rear fixed stop.
► If required, push the squeegee manually over the park plate to the rear fixed stop.
► In the station software, select the Setup
view(1) and then the Locations area (2).
► Select the Table (3) on which the LDU is
set up.
► Select the icon of the LDU(1).
► Click on the Settings... button (2).
► Select the Dipping area tab (1).
► Click on the Reference run button (2).
The LDU performs a reference run.