Test Research, Inc. TR7600 SIII Ser ies User G uide – Cam era Calibr ation 9 3) Under the left-in r ight-out board condition, please put the c alibration b oard into the machine shown as below. Figure 6: Put the Calibrat…

100%1 / 85
Test Research, Inc.
8 TR7600 SIII Series User Guide – Camera Calibration
2) Set up FFC (Flat-Field Correction)
a) Click [Inspect] [Parameters].
Figure 4: Set Up FFC
b) Click [FFC Configuration]
I. If Period field is -1, the machine won't do FFC.
II. If Period field is 0, the machine will do FFC automatically every time
before scanning the board.
III. If Period field is a positive number, such as 50, the machine will do FFC
every 50 minutes automatically.
IV. For manual FFC with board width more than 250 mm, please click [Front]
to use front correction boards to do FFC.
V. For manual FFC with the board width less than 250mm, please click
[Rear] to use the rear correction board to do FFC.
Figure 5: Inspection Parameters
c) Click [OK] to exit.
Test Research, Inc.
TR7600 SIII Series User Guide – Camera Calibration 9
3) Under the left-in right-out board condition, please put the calibration board into the
machine shown as below.
Figure 6: Put the Calibration Board into the Machine
4) Set up the scan parameters:
a) Click [Program] [Set Scan Info].
Figure 7: Set Up Scan Info
b) Input the scan parameters and click [Scan] to scan the board. Click [Ok].
Figure 8: Set Up Scan Parameters
Test Research, Inc.
10 TR7600 SIII Series User Guide – Camera Calibration
c) Right-click the mouse on the screen, and choose [DisplayOriginal].
Figure 9: Original
d) In the toolbar, click [UtilitySystem ConfigurationData Bit Range], and choose
[Auto Range].
Figure 10: Utility
Figure 11: Auto Range