Test Research, Inc. 58 TR7600 SI II Series User Guide – Camera Ca libration 3.9 Laser Offset Uses th e square hole’s position as a refere nce to tell laser about its position. 1) Pu t th e calibration board into the ma…

Test Research, Inc.
TR7600 SIII Series User Guide – Camera Calibration 57
5)
Click on [
←] or [→] button to set the mode as [Shift].
Figure 104: Shift
6) The window should display the value [0.000].
Figure 105: 0.000
7) Click on [
←] or [→] button to set the mode as [R.V.].
Figure 106: RV
8) The setup is finished.
Figure 107: The Setup Is Finished

Test Research, Inc.
58 TR7600 SIII Series User Guide – Camera Calibration
3.9 Laser Offset
Uses the square hole’s position as a reference to tell laser about its position.
1) Put the calibration board into the machine.
Figure 108: Calibration Board
2) Click on [Laser Offset].
Figure 109: Laser Offset
3) Choose [0] in the [Sensor Index] field.
Figure 110: Choose Laser Sensor 0

Test Research, Inc.
TR7600 SIII Series User Guide – Camera Calibration 59
4) Click on [Set Scan Info(XRay)] to set up the scan paramaters and click on [OK].
Figure 111: Set Scan Info.
5) Do not use the [Scan] buttons shown as below to scan the board.
Figure 112: Don’t Use These Buttons to Scan the Board
6) Click on [Scan (XRay)] to scan the board and the main program will calculate the
required data.