CP-842E-842ME System Reference-SYS-CP842-10E - 第47页
Machine System >> Basic Operation SYS-CP842-1.0E 4-11 Delayed Stop Delayed Stop skips parts which cause an erro r , and carries out recovery after all other sequences are complete. If the recovery limit for a part …

Machine System >> Basic Operation
4-10
SYS-CP842-1.0E
Setting the Recovery Timing
Users can specify when Recovery is carried out, if an error occurs during part inspec-
tion. There are four modes available, [Immediate Stop], [Delayed Stop], [Immediate
Continuous], and [Delayed Continuous]. The key differences between these modes is
when recovery is performed, and what action is taken in response to the recovery limit
for a part being reached.
Procedure
1 Press [Recovery] at the [Main] screen, the [Recovery] screen displays.
2 [Immediate], [Delayed], can be selected from the Recovery Timing section.
Select either [Stop] or [Continuous] at the “Stop Mode At Recovery Up” section
of the screen.
3 Press [Close] to enter the setting and return to the [Main] screen.
Immediate Stop
Immediate Stop will reallocate the placement sequence for which an error occurred as
soon as possible. If the recovery limit for a part is reached, the machine stops. In this
case, the set order of the sequences is disturbed by the insertion of recovery sequences.
The flow of processing is shown in the following diagram.
Delayed
Immediate
Recovery Timing
Continuous
Stop
Stop Mode At Recovery Up
C7SS2006
Immediate Stop
Recovery occurs
Recovery sequence immediately allocated for placement
Recovery limit reached
Machine stops
Standard sequences
also allocated
Operation continues if
a next device
has been set.
C73OM025a

Machine System >> Basic Operation
SYS-CP842-1.0E 4-11
Delayed Stop
Delayed Stop skips parts which cause an error, and carries out recovery after all other
sequences are complete. If the recovery limit for a part is reached, the machine stops.
In this case, the order of the placement sequences is not disturbed.
The flow of processing is shown in the following diagram.
Delayed Stop
Recovery occurs
Placement of parts
Recovery sequence is put to the end
Recovery limit reached
Recovery sequences are allocated
Standard sequences are completed
Machine stops
Operation continues if
a next device
has been set.
Repeated until
standard sequences
are complete.
C73OM026a

Machine System >> Basic Operation
4-12
SYS-CP842-1.0E
Immediate Continuous
Immediate Continuous mode works in the same manner as the Immediate Stop mode,
except for when a recovery limit is reached. Instead of stopping, the machine
attempts those sequences missed for the recovery limit part after the rest of the
sequences are complete. If the recovery limit is reached again after attempting those
remaining sequences for a second time, then the machine is stopped by a recovery
limit error.
The flow of processing is shown in the following diagram.
Immediate Continuous
Recovery occurs
Placement of parts
Recovery sequence immediately allocated for placement
Recovery limit reached
Standard sequences are completed
Machine stops
Recovery sequences are allocated
Recovery limit part is put to the end
Recovery limit reached
Operation continues if
a next device has
been set.
Repeated until
standard sequences
are complete.
C73OM027a