Machine System >> Editing Production Programs On t he Machine SYS-CP842-1.0E 4-51 Display Item Explanations 1. [Sequence]: Displays the sequence progression status as a ba r graph which indicates the percent age (%…

100%1 / 220
Machine System >> Editing Production Programs On the Machine
4-50
SYS-CP842-1.0E
Simulation Screen
Simulations are performed from this screen.
Screen Button Explanations
A. [Production Start Sequence No.]: Switches to the sequence search screen.
B. [Production Program Edit]: Switches to the production program editing
screen.
C. []: Specifies a simulation in the continuous opera-
tion mode.
D. [Q]: Specifies a simulation in the step operation’s
repeat mode.
E. []: Specifies a simulation in the step operation’s 1-
sequence feed mode.
F. [Interval Timer]: Sets the length of intervals between sequences
for simulation in the continuous operation mode.
G. [Close]: Returns to the program switching screen. A dia-
log box displays at this time inquiring if the pro-
duction program is to be saved. When saved,
production program overwriting occurs.
Load a board, and then press START to commence simulation.
FUJI
ErrorOperator
JOG:X Y CAM
Servo CountGEM
CCD Monitor
SimulationFUJI_CP7_2001
Front
Close
Sequence (%) :
0
Sequence
Number :
Device Number :
1-0-1-0
123
Operation Mode
Continuous Step
Interval Timer
Starting
Sequence
Program Editor
[sec]
1
Set Switch
CP7S2008E
A
B
C
D
E
F G
1
23
4
Machine System >> Editing Production Programs On the Machine
SYS-CP842-1.0E 4-51
Display Item Explanations
1. [Sequence]: Displays the sequence progression status as a bar
graph which indicates the percentage (%).
2. [Sequence No.]: Displays the sequence number for which image acquisi-
tion (by mark camera) is occurring.
3. [Device No.]: Displays the stage number, group number, slot number,
and sub-slot number of the device for the displayed
[Sequence No.] (see item 2 above).
4. [Monitoring Preview]: Displays the panel position of the sequence for which
image acquisition (by mark camera) is occurring.
Operation Explanation
1 Start
•The START button lamp blinks except at the times shown below.
Simulation begins when the blinking START button is pressed.
(1) When at the sequence screen.
(2) When editing data (a ten-key pad or an input dialog box displays).
•Screen buttons are disabled during a simulation.
2 Continuous operation
•Intervals are inserted between each sequence. The interval length is set at the
simulation screen.
•Operation continues until all sequences in the production program are com-
pleted. If the CYCLE STOP button is pressed while operation is in
progress, a stop does not occur until the current sequence is completed.
3 Step operation
•If started when there is no panel present, the initial F-mark reading sequence
for panel loading is performed, and operation then stops.
•If the [Q] button is pressed, the same sequence is repeated.
•If the [] button is pressed, processing proceeds 1 sequence at a time.
4 Specifying the initial sequence
•The initial sequence can be specified at all times.
5 Saving the production program
•When the [Close] button is clicked after editing a production program, a dialog
box displays inquiring if the production program is to be saved. If saved,
production program overwriting occurs. If not saved, the edited content is
abandoned.
Machine System >> Editing Production Programs On the Machine
4-52
SYS-CP842-1.0E
Test Placement Panel
Test placement is performed from this screen.
Screen Button Explanations
A. [Production Program Edit]: Switches to the production program editing screen.
B. [Production Start Sequence No.]: Switches to the sequence search screen.
C. []: Specifies a test placement in the continuous operation
mode.
D. []: Specifies a test placement the step operation mode.
E. [Unload]: When this button is clicked, all other screen buttons
except for the [Close] button are disabled. The START
button can then be pressed to unload the panel.
F. [Close]: Returns to the program switching screen. A dialog box
displays at this time inquiring if the production pro-
gram is to be saved. When saved, production program
overwriting occurs.
Load a board, and then press START to commence a test run.
FUJI
ErrorOperator
JOG:X Y CAM
Servo CountGEMCCD Monitor
TestFUJI_CP7_2001
Front
Close
Production
Editior
Starting
Sequence
Operation Mode
Sequence (%) :
0
Sequence
Number :
Device Number :
1-0-1-0
123
Continuous Step
Unload
Set Switch
B
C
D
EF
12
3