SOM-2080-001_w.pdf - 第101页
98 SOM-2080 6.6 Recognition Communication 1005-001 6.6 Recognition Communication T able 8 Erroe ID Error Name, Description, Cause, and Remedy 450101 Recog Comm. Error Recognition Error Code. ----- 450102 Recog Comm. Erro…

97
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
448102 Tray resupply operation error
Operation start error
-----
448103 Tray resupply operation error
Operation completion time out
-----
448104 Tray resupply operation error
An error occurred in the operation.
-----
6.5 Tray Feeder 2
1005-001

98
SOM-2080
6.6 Recognition Communication
1005-001
6.6 Recognition Communication
Table 8
Erroe ID Error Name, Description, Cause, and Remedy
450101 Recog Comm. Error
Recognition Error Code.
-----
450102 Recog Comm. Error
Time-Out Error
Turn off the machine by pressing the emergency stop and after restarting it,
perform the zeroing operation.
450103 Recog Comm. Error
GUI starting failure.
-----

99
SOM-2080
6.7 PEC Recognition
1005-001
6.7 PEC Recognition
Table 9
Erroe ID Error Name, Description, Cause, and Remedy
460101 PEC Inspection
PEC Mark #1 (Global)
-----
460102 PEC Inspection
PEC Mark #2 (Global)
-----
460103 PEC Inspection
PEC Mark #3 (Global)
-----
460104 PEC Inspection
PEC Mark #1 (Image)
-----
460105 PEC Inspection
PEC Mark #2 (Image)
-----
460106 PEC Inspection
PEC Mark #3 (Image)
-----
460107 PEC Inspection
PEC Mark #1 (Local)
-----
460108 PEC Inspection
PEC Mark #2 (Local)
-----
460109 PEC Inspection
PEC Mark #3 (Local)
-----
46010a PEC Inspection
Land PEC Mark #1
-----
46010b PEC Inspection
Land PEC Mark #2
-----
46010c PEC Inspection
Land PEC Mark #3
-----
460201 PEC Inspection Test
PEC Inspection was failed.
-----
460301 PEC Light Teaching
PEC Light Teaching was failed.
-----