SOM-2080-001_w.pdf - 第107页
104 SOM-2080 6.9 Automatic Setup 1005-001 Erroe ID Error Name, Description, Cause, and Remedy 49060d Conveyor Width Automatic Adjustment The L1 axis was not zeroed successfully. ----- 49060e Conveyor Width Automatic Adju…

103
SOM-2080
6.9 Automatic Setup
1005-001
6.9 Automatic Setup
Table 11
Erroe ID Error Name, Description, Cause, and Remedy
490601 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L1 axis might
be located lower than the pass line.
-----
490602 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L2 axis might
be located lower than the pass line.
-----
490603 Conveyor Width Automatic Adjustment
A PCB exists on the L conveyor.
-----
490604 Conveyor Width Automatic Adjustment
A PCB exists on the R conveyor.
-----
490605 Conveyor Width Automatic Adjustment
A PCB exists on the R conveyor.
-----
490606 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L axis might
be located lower than the pass line.
-----
490607 Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed.
-----
490608 Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed.
-----
490609 Conveyor Width Automatic Adjustment
The PWC axis is not zeroed completely.
-----
49060a Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed
through an smooth inching operation.
-----
49060b Conveyor Width Automatic Adjustment
The current position of the L1 axis is not managed because the axis is not zeroed.
-----
49060c Conveyor Width Automatic Adjustment
The current position of the L2 axis is not managed because the axis is not zeroed.
-----

104
SOM-2080
6.9 Automatic Setup
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
49060d Conveyor Width Automatic Adjustment
The L1 axis was not zeroed successfully.
-----
49060e Conveyor Width Automatic Adjustment
The L2 axis was not zeroed successfully.
-----
49060f Conveyor Width Automatic Adjustment
The BPC axis was not zeroed successfully.
-----
490610 Conveyor Width Automatic Adjustment
The current position of the X1 axis is not managed because the axis is not
zeroed.
-----
490611 Conveyor Width Automatic Adjustment
The current position of the X2 axis is not managed because the axis is not
zeroed.
-----
490612 Conveyor Width Automatic Adjustment
The current position of the Y axis is not managed because the axis is not zeroed.
-----
490613 Conveyor Width Automatic Adjustment
The escape operation of the X axis ended in an error condition.
-----
490614 Conveyor Width Automatic Adjustment
The escape operation of the Y axis ended in an error condition.
-----
490615 Conveyor Width Automatic Adjustment
The support pins could not ascend because the maximum conveyor width was
not obtained.
-----
490616 Conveyor Width Automatic Adjustment
The current PCB width was not obtained because the pattern program data is not
defined.
-----
490617 Conveyor Width Automatic Adjustment
Software limit
-----
490618 Conveyor Width Automatic Adjustment
There is a PCB on the conveyor
-----
490619 Conveyor Width Automatic Adjustment
Failed in Program Change Operation(Data Error).
-----

105
SOM-2080
1005-001
6.9 Automatic Setup
Erroe ID Error Name, Description, Cause, and Remedy
49061a Conveyor Width Automatic Adjustment
Failed in Program Change Operation(Time out).
-----
49061b Conveyor Width Automatic Adjustment
Backup Base zeroing Error.
-----
49061c Conveyor Width Automatic Adjustment
Head Up/Down Axis Zeroing Error.
-----
49061d Conveyor Width Automatic Adjustment
The PCB was detected on the Input conveyor.
Please remove the P.C.B on a Input conveyor.
49061e Conveyor Width Automatic Adjustment
The PCB was detected on the Cnvr Positioning1.
Please remove the P.C.B on a Cnvr. Positioning1.
49061f Conveyor Width Automatic Adjustment
The PCB was detected on the central conveyor.
Please remove the P.C.B on a center conveyor.
490620 Conveyor Width Automatic Adjustment
The PCB was detected on the Cnvr Positioning2.
Please remove the P.C.B on a Cnvr. Positioning2.
490621 Conveyor Width Automatic Adjustment
The PCB was detected on the Output conveyor.
Please remove the P.C.B on a Output conveyor.
490622 Conveyor Width Automatic Adjustment
The width of arrangements of the conveyer is set smaller than 56mm.
Please adjust the setting (width + clearance) to 56mm or more.
490690 Conveyor Width Automatic Adjustment
Auto Set-up Error(Others).
-----
490701 Nozzle set-up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set-up
Motor Error Detection.
-----
490703 Nozzle set-up
Nozzle Stocker Shutter open/close failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490704 Nozzle set-up
Nozzle Stocker up/dowon failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.