1 12 SOM-2080 6.9 Automatic Setup 1005-001 Erroe ID Error Name, Description, Cause, and Remedy 496605 Conveyor Width Automatic Setup (Output conveyor W2) The conveyor cover opened. Close the conveyor cover. 496606 Convey…

100%1 / 179
111
SOM-2080
6.9 Automatic Setup
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
496406 Conveyor Width Automatic Setup (Positioning conveyor W2)
Voltage reduction on the power source was detected.
Check the transfer driver.
496407 Conveyor Width Automatic Setup (Positioning conveyor W2)
OT (+) was detected during auto operation.
Perform zeroing operation.
496408 Conveyor Width Automatic Setup (Positioning conveyor W2)
OT (-) was detected during auto operation.
Perform zeroing operation.
496501 Conveyor Width Automatic Setup (Output conveyor W1)
The initialization is imperfect.
Power on the machine again. The transfer driver has a problem.
496502 Conveyor Width Automatic Setup (Output conveyor W1)
It failed in zeroing operation.
Perform zeroing operation.
496503 Conveyor Width Automatic Setup (Output conveyor W1)
An alarm for the interference is occurring.
-----
496504 Conveyor Width Automatic Setup (Output conveyor W1)
DI was detected.
-----
496505 Conveyor Width Automatic Setup (Output conveyor W1)
The conveyor cover opened.
Close the conveyor cover.
496506 Conveyor Width Automatic Setup (Output conveyor W1)
Voltage reduction on the power source was detected.
Check the transfer driver.
496507 Conveyor Width Automatic Setup (Output conveyor W1)
OT (+) was detected during auto operation.
Perform zeroing operation.
496508 Conveyor Width Automatic Setup (Output conveyor W1)
OT (-) was detected during auto operation.
Perform zeroing operation.
496601 Conveyor Width Automatic Setup (Output conveyor W2)
The initialization is imperfect.
Power on the machine again. The transfer driver has a problem.
496602 Conveyor Width Automatic Setup (Output conveyor W2)
It failed in zeroing operation.
Perform zeroing operation.
496603 Conveyor Width Automatic Setup (Output conveyor W2)
An alarm for the interference is occurring.
-----
496604 Conveyor Width Automatic Setup (Output conveyor W2)
DI was detected.
-----
112
SOM-2080
6.9 Automatic Setup
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
496605 Conveyor Width Automatic Setup (Output conveyor W2)
The conveyor cover opened.
Close the conveyor cover.
496606 Conveyor Width Automatic Setup (Output conveyor W2)
Voltage reduction on the power source was detected.
Check the transfer driver.
496607 Conveyor Width Automatic Setup (Output conveyor W2)
OT (+) was detected during auto operation.
Perform zeroing operation.
496608 Conveyor Width Automatic Setup (Output conveyor W2)
OT (-) was detected during auto operation.
Perform zeroing operation.
496717 Standard Position Adjustment Error
An overrun sensor (+) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496718 Standard Position Adjustment Error
An overrun sensor (-) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496727 Standard Position Adjustment Error
An overrun sensor (+) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496728 Standard Position Adjustment Error
An overrun sensor (-) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496737 Standard Position Adjustment Error
An overrun sensor (+) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
496738 Standard Position Adjustment Error
An overrun sensor (-) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
496747 Standard Position Adjustment Error
An overrun sensor (+) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
496748 Standard Position Adjustment Error
An overrun sensor (-) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
496757 Standard Position Adjustment Error
An overrun sensor (+) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.
496758 Standard Position Adjustment Error
An overrun sensor (-) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.
496767 Standard Position Adjustment Error
An overrun sensor (+) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.
113
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
496768 Standard Position Adjustment Error
An overrun sensor (-) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.
496801 Transfer Communication Error
An error occurred in the transfer driver comunications.
1. Check the communications cable.\r\n2. Check the power cable.\r\n3. Check
transfer motor driver's address setting.\r\n4. Check the fuse[F1,F2,F3] on [U85] in
CPU2. If the fuse is blown, replace [U85] board.
496802
-----
496803
-----
496804
-----
6.9 Automatic Setup
1005-001